<br /> Project_Report
<br /> Project Title: Mike Vanyo
<br /> Project Date: 8/11/14
<br /> Client Name: Mark Williams
<br /> Company Name: DJ's Heating&Air Conditioning
<br /> Company Representative: Rick Anderson
<br /> Company Address: 6060 LaBeaux Ave NE
<br /> Company City: Albertville, MN 55301
<br /> Company Phone: 763-497-6845
<br /> Company Fax: 763-497-2695
<br /> Company E-Mail Address: rick@djsonline.com
<br /> Company Website: www.djsonline.com
<br /> Company Comment:
<br /> aJG.Q• � : a ' � ': .�, ... z`�,�e x s�'�+<,.. :i � r� ;,"r"_'��.`: �',"s� * `�z��� ��s ^ _,
<br /> .._� .....,._.. _.���_ �y.,...,,�___:» ._.._.�.: ..._.,.._.,::�.._.S!..e.e.�.....,n..��`.:�.tP�,3 �.m�.�:,ui�.��.�._�.,.,�.�,..___.__,_u�:r..<.. �'�a:�,.��.°a.:o�:..,.�'_:.i.._._...,.--�._ _ _-!
<br /> Reference City: Minneapolis, Minnesota
<br /> Building Orientation: Front door faces East
<br /> Daily Temperature Range: Medium
<br /> Latitude: 44 Degrees
<br /> Elevation: 834 ft.
<br /> Altitude Factor: 0.970
<br /> Outdoor Outdoor Outdoor Indoor Indoor Grains
<br /> Bulb Wet Bulb Rel.Hum Rel.Hum Drv Bulb Difference
<br /> Winter: -12 -12.38 n/a 30% 70 31.16
<br /> Summer: 89 73 47°k 50% 75 34
<br /> -� ,��
<br /> � �' ���� ��' � ��'" � � ,
<br /> 'I'otalFBuilding Supply CFM: 1,653 CFM Per Square ft.: 0.308
<br /> Square ft. of Room Area; 5,359 Square ft. Per Ton: 1,435
<br /> Volume(ft')of Cond. Sp�ce: 46,237
<br /> ���A y�V ¢ �'� "i`
<br /> ��
<br /> Total Heating Required Including Ventilation Air: 101,214 Btuh 101.214 MBH
<br /> Total Sensible Gain: 36,391 Btuh 81 %
<br /> Total Latent Gain: 8,411 Btuh 19 %
<br /> Total Cooling Required Including Ventilation Air: 44,802 Btuh 3.73 Tons(Based On Sensible+ Latent)
<br /> �
<br /> Rhvac is an ACCA approved Manuat J and Manual D computer program.
<br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
<br /> your design conditions.