r �- <br /> City of Orono Septic System Approval <br /> ISTS DESIGN <br /> YES O NA <br /> ISTS design specifications shall include proposed flows or other sizing information,minimum sewage tank <br /> capacity,minimum soil treatment area requirements,a plan of the component layout and all other information <br /> necessary to assure the City that the ISTS is designed and will be constructed to receive,treat and dispose of all <br /> of the sewa e from the buildin served. <br /> Setbacks <br /> Feature Sewa Tank feet Soil Treatment Area feet <br /> Dee well 50 50 <br /> WeUand 50 50 <br /> General Develo ment Lake 75 75 <br /> Recreational Develo ment Lake 75 75 <br /> Natural Environment ake 150 150 <br /> Tributaries/Streams 75 75 <br /> Drivewa s,sidewalks,decks and other hardcover 10 10 <br /> Pro ert lines,buildin s and buried i es 10 20 <br /> �^ Lawn s rinkler s stems 10 10 <br /> Sewa Tanks. <br /> Number of Bedrooms Tanks Liquid Ca acities gallons <br /> 4 or less 1,000+ 1,000 r ardless of arba e dis osal use <br /> 5 or 6 1,250+ 1,000 re ardless of arba e dis osal use <br /> 7,8 or 9 1,500+ 1,500 re ardless of arba e dis osal use <br /> 10 or more Sewa e tanks shall be sized as other establishments er MN Rules 7080. <br /> Pum in Stations. <br /> In order to standardize installation and electrical connection methods,the following pumping station requirements <br /> must be met in addition to MN Rules cha ter 7080 <br /> Electrical connection: <br /> / A waterti ht,lockable electrical box must be mounted on a four-inch b four-inch treated redwood or cedar st. <br /> � All electrical connections shall be made within the box. Pump connection must not be made using a direct line <br /> lu -in onl . Wire ent to the electrical box shall be sealed with a waterti ht material such as foam or u . <br /> Alarm and um floats shall be on se arate electrical circuits. <br /> Electrical wire from the power supply must not run over any tanks and must be laid beside the tanks and placed in <br /> � conduit alon the electrical ost. <br /> Electrical cords from the pump and floats must be run through a two-inch PVC(or equivalent)conduit(schedule <br /> 80)with a one-inch gap between the conduit and the electrical box. Electrical cords must not run through or under <br /> � the manhole cover. Wires must not have round contact. <br /> Pum in' `Chamber: <br /> Pressure pipe exiting the pumping chamber must be laid on a uniform slope up to the soil treatment area for <br /> proper drain back. The pressure pipe must be sleeved and i�side a larger diameter pipe for additional support if <br /> � spanning ground that has been excavated. If the pipe at the tank must be lower than union to get elevation for <br /> drain back,a one- uarter inch wee hole must be used. <br /> When soil depths above the pressure distribution pipe is less than 3%Z feet,insulation must be added to achieve <br /> / an insulating factor equal to 3'/z feet of soil to decrease the potential for freezing(Styrofoam or concentric piping <br /> � are acceptable methods). Piping under hardcover,such as tennis courts or driveways shall be insulated pipe or <br /> e uivalent. <br /> A reserve capacity equaling 75%of the anticipated daily flow must be allowed into the pumping chamber between <br /> the alarm activation level and the um tank inlet. <br /> Protection of d��infield ar.ea. <br /> � Proposed drainfield areas shall be identified and marked off on the lot at the time of the site evaluation and prior to <br /> any construction or grading occurring in the area. The drainfield area shall remain undisturt�ed until drainfield <br /> construction is commenced. No vehicular traffic shall be allowed in the drainfield area either before or after <br /> d 'nfield installation. <br /> ACCEPTED DENIED by the Metro West on behalf of the City of Orono subject to existing regulations and the <br /> following condition : <br /> �e C m ..�.,d•�. A- �LK r•- �c �'+v �s g---- o-s�..� <br /> Inspe ons required: / �J / <br /> 1. �vL(S f So, f Va✓� {��A�i7��,po� 5. <br /> 2. o�.ce ... . 6. <br /> 3. �'� .� �v�.k ��0.,,or. 7. <br /> 4. (- v t ! K+- �� ts��'� 8. <br /> �r rf / [ <br /> B�y���� Printed Name: dC,�LE� /L� `1�13w Date: vri <br /> w:\septic�septic system approval revised 2-2015.docx <br /> Page 2 of 2 <br />