My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-0554 - septic replaacement
Orono
>
Property Files
>
Street Address
>
P
>
Pine View Drive
>
1100 Pine View Drive - 28-118-23-42-0010
>
Septic
>
2015-0554 - septic replaacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:25:37 PM
Creation date
7/5/2018 1:28:22 PM
Metadata
Fields
Template:
x Address Old
House Number
1100
Street Name
Pine View
Street Type
Drive
Address
1100 Pine View Drive
Document Type
Septic
PIN
2811823420010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ OSTP B�sic Pump Selection Desi�n �k_ <br /> �� LINIVERSITY -�-� `' `�`" <br /> Minnesota Poilution ' �����*�; <br /> Control A enc Worksheet OF MINNESOTA�� ,� ,�,L,�r,,, <br /> 1. PUMP CAPACITY Project ID: v 11.09.22 <br /> Pumping to Grovity or Pressure Distribution: Q �rava.y Q Resare Setection required 2 <br /> 1. If pumping to gravity enter the gallon per minute of the pump: �GPM (f0-45 gpm) <br /> 2. If pumping to a pressurized distribution system: 29.0 GPM <br /> (Une i f oj Pressure Distributfon) <br /> trea mm�spst <br /> a co�m a asceuye <br /> 2. HEAD REQUIREMEN7'S I �; . <br /> �+wa` <br /> A. Elevation Difference �7 � S„qar�"` <br /> between pump and point of discharge: ^'e1pi� E�„a,b,,:" <br /> �����e <br /> B. Distribution Head Loss: �ft -_- - <br /> ...._- __. <br /> C. Additional Head Loss: ��ft due to s ----------------------------- -------------• <br /> ( P�ial equipment,etc.) <br /> Table I.Friction Loss in PlasNc Pipe per 100ft <br /> Distribution Head Loss <br /> Gravity Distribution = oft Flow Rate P� e Qiameter(inches) <br /> IGPM) 1 1.25 1.5 2 <br /> Pressure Distribution based on Mi�imum Average Head 10 9.1 3.1 1.3 0.3 <br /> Value on Pressure Distribution Worksheet: 12 12,g 4.3 t.8 0.4 <br /> Minimum Avera e Head Dist ibution Head Loss �4 �7,0 5.7 2.4 0.6 <br /> 1ft 5ft �6 2�,$ 7.3 3.0 0.7 <br /> 2ft I 6ft 18 9.1 3.8 0.9 <br /> 5ft 1�t 20 11.1 4.6 1.1 <br /> 25 ( 16.8 6.9 1.7 <br /> D. 1.Supply Pipe Diameter: 2.0 in 30 23.5 9.7 2.4 <br /> 35 12.9 3.2 <br /> 2.SuPP�Y RPe�3�: 160 fk 40 16.5 4.1 <br /> E. Friction loss in Piastic Pipe per 100ft from Tadt�I: 45 20.5 5.0 <br /> ' S0 6.1 <br /> Friction Loss= 2.23 ft per 10Qft of pipe 55 7.3 <br /> bU 8.6 <br /> p, Detertnine Equivalent Pfpe Length from pump disGharge to soil dispersal area discharge 65 10.0 <br /> point. Estimate by adding 25%to supply pipe lerx�th for fitting loss. Supp/y Pipe Length <br /> 70 11.4 <br /> (0.2) X 1.25=Equivalent Pipe Length 75 13.0 <br /> 85 16.4 <br /> 160 ft X 1.25 = 200.0 ft 95 20.1 <br /> G. Calculate Supply Friction Loss by multiplying FricQion Loss Per 100ft (Line E)by the Equivalent Pipe Length (Line F)and divide by 100. <br /> Supply Frittion Loss= <br /> 2.23 ft per 10oft X 200.0 ft = 100 = 4.5 ft <br /> H• Total Hend requirement is the sum of the Elevatiar►Difference (Line A),the Distribution Head Loss(Line B),Additional Head Loss(Line C),and the <br /> Supply Friction Loss(Line G) <br /> 17.0 ft + 5.0 f� + ��ft + 4.5 ft = 26.5 ft <br /> 3. PUMP SELECTION <br /> A pump must be selected to detiver at teast 29 GPM(Line 1 or Line 2)with at teast 2] feet of total head. <br /> Comments: <br />