My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-0554 - septic replaacement
Orono
>
Property Files
>
Street Address
>
P
>
Pine View Drive
>
1100 Pine View Drive - 28-118-23-42-0010
>
Septic
>
2015-0554 - septic replaacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:25:37 PM
Creation date
7/5/2018 1:28:22 PM
Metadata
Fields
Template:
x Address Old
House Number
1100
Street Name
Pine View
Street Type
Drive
Address
1100 Pine View Drive
Document Type
Septic
PIN
2811823420010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- OSTP Des��n Summa Worksheet UNIVERSITY w':� �� <br /> Minnesota Pollution � OF MINNESOTA � ��� "'"� <br /> Control Agency ��.��� <br /> �operty owneric�ient: Gorden James nstruction Project ID:� ���'�'� <br /> Site Address: 1100 Pine View Drive(S te A) <br /> 1. AVERAGE DESIGN FLOW: <br /> A. Desiqn F(ow: 60� Gdllons Per D (GPD) Note: The esttmated destgn Jlow is mraidered a pevk jlow rote ir►ciuding n sofety <br /> fnctor.For tong tertn performante,the average daily j/ow is recommended to be< <br /> B. Septic Tank capacity: 2250 Gatlons 6o%of this rolue. <br /> �, Number of Septic Tnnks or Compartments: �� Effluent Screen&Alarm? NO <br /> Type of Soa Treahr�+nt ad Dfspersal Area* I Type of Dstri6ution• <br /> Q Trencha p Bed �Mound Q At de O�v�,��n QQ Pressure Distr�utlon-I.evd Q Pressue Da6ibution-Unkvel <br /> O o�D�. Q r�dd�,y Tar�O <br /> *Selection Required Benchmark Elev= 1014.8 ft <br /> System Typs Benchmark Location: spike in power pole <br /> �Type I Q Type II ❑Type III i�Type IV ❑Type V TYPe of Distribution Media: <br /> Rock <br /> D. Pump Tank 1 Capacity: �Gallons Pump Tonk 2 Caparity: �Gallons <br /> 2. SITE EVAIUATION: <br /> A. Depth to Limtting Layer: 28 'nches 2.3 ft Elevation @ location of Limiting Layer: 1013.7 ft <br /> B. Measured Percent Lnnd Slope: 4�0 % 0.0 Locatbn: ShOUldef <br /> C. Soit Texture: LOdm Perc Rate• ��MPI <br /> D. Soil Hydraulic Loading Rate: 0. 0 GPD/ftZ E.Coniour Loading Rate 12.0 Galfft <br /> 3. DESIGN SUMMARY <br /> Trench Design Summary <br /> Dispersal Area �ft2 Sidewall Depth �in Trench Width �;n <br /> Total Lineat Feet �ft ' Number of Trenches �� Maximum Trench Depth �in <br /> Designers Max Trench Depth in <br /> Bed Design Summary <br /> Absorption Area �ftz Media Below Pipe ��in Bed Length ��ft <br /> Bed Width �ft Mdximum Bed Depth �9n Designers Max Bed Depth �in <br /> Mound Design Summary <br /> Absorption Area 500 ft2 Bed length 50 ft Bed Width 10.0 ft <br /> Absorption Width 20.0 ft I Clean Sand Lift 1.0 ft Berm Width (slope 0-1%)��ft <br /> Upslope Berm Width 10.0 ft Downslope Berm Width 16.0 ft Endslope Berm Width 10.0 ft <br /> Total System Length 7Q ft ' Total Sysiem Width 36 ft <br /> At-Grade Design Summary <br /> Absorption Bed Width �ft Absorption Bed Length �ft System Height �ft <br /> Absorption Bed Area �ftz Upslope Bertn Width �ft Downslope Berm Width �ft <br /> Endslope Berm Width �ft System Length �_�ft System Width �ft <br />
The URL can be used to link to this page
Your browser does not support the video tag.