My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00042 - new structure
Orono
>
Property Files
>
Street Address
>
P
>
Pine View Drive
>
1100 Pine View Drive - 28-118-23-42-0010
>
Permits/Inspections
>
2015-00042 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:25:36 PM
Creation date
7/5/2018 1:28:09 PM
Metadata
Fields
Template:
x Address Old
House Number
1100
Street Name
Pine View
Street Type
Drive
Address
1100 Pine View Drive
Document Type
Permits/Inspections
PIN
2811823420010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�� 1 � s � <br /> ���� <br /> C ITY OF ORONO <br /> � ,� Street Address: Mailing Address: Telephone(952)249-4600 <br /> y�, � 2750 Keliey Parkway P.O.Box 66 Fax (952)249-4616 <br /> r9kESH���G Orono,MN 55356 Crystal Bay,MN 55323 www.ci.orono.mn.us <br /> February 3,2015 <br /> Gordon James Construction <br /> Attention: Jeremy <br /> PO Box 306 <br /> Maple Plain, MN 55359 <br /> Re: Building Permit Application#�015-00042 <br /> 1100 Pine View Drive <br /> On January 13, 2015 the City received!a building permit application for a new single family home at 1100 Pine View <br /> Drive. Staff conducted a preliminary review based on the information provided and recommends the following items <br /> be submitted or revised in order for you�r application to be considered complete and for the plan review to continue: <br /> 1. Certificate of Survey. The City� Engineer has reviewed the survey and made the following comments. Please <br /> provide two copies of an updated,full size certificate of survey which meets all of the Citys survey standards <br /> (enclosed)addressing the comments below. <br /> a. The grading plan indic�tes a plan to grade within Septic Area B. Disturbing the ground in septic area <br /> B would likely invalidate it as a potential septic site. In addition the survey does not depict the <br /> proposed septic tank Ipcations as required per the City's survey requirements. <br /> b. The grading plan indicates earthwork will be occurring within the tree preservation easement. The <br /> grading should be revised and or a detailed tree preservation plan should be submitted before the <br /> city approves any grading within the easement area. Grading in the easement area has the potential <br /> to harm or kill the existing trees. The grading plan/survey does not depict trees over 6" diameter as <br /> required by the city's survey requirements within areas of proposed disturbance. <br /> c. The existing drainage ways along Pine View Drive and 6th Avenue N.are not depicted as required per <br /> the City's survey requirements. <br /> d. The berm depicted on the north of the property appears to be about 400 CY by itself. Please provide <br /> earthwork calculations for the project. <br /> e. The Survey does nat' depict any construction erosion control measures. A silt fence or other <br /> appropriate erosion control mechanism should be planned for and must be installed and inspected <br /> by the City prior to any land disturbing activities. The Contractor must provide a minimum 24 hour <br /> notice prior to inspection. <br /> f. The existing driveway that runs along the east side of the property is not depicted as required by the <br /> City's survey requirerrhents. This existing driveway and culvert should be shown to be removed. A <br /> planting plan should be submitted showing at a minimum trees or other native species being planted <br /> on the north and south ends of the existing driveway to close off the access. <br /> g. The survey does not depict the location of a proposed well. <br />
The URL can be used to link to this page
Your browser does not support the video tag.