� � � S� c� � � SQ <br /> � � t� . c� <br /> � � <br /> I � <br /> Joseph Olson D.B.A. ��� �� n�.Vi�iW �� <br /> Rusty Olson's--Soil and Percolation Testing �,L�-� �� <br /> Joseph J. Olso�--MPCA Liceose #810 <br /> 11481 Riverview Rd. NE, Hanover, MN 55341 <br /> (763) 498-8779 fax (763) 498-8290 <br /> July 24,20]2 <br /> John Lein <br /> Proposed lot 4 2700 6`''Ave N <br /> .__.. <br /> Orono,Hennepin County <br /> This on-site Sewage Treatment System is partially designed for a Type l,five-bedroom home in <br /> accordance with the Minnesota Pollution Control Agency Chapter 7080 and local ordinances. <br /> Once the house size, location and septic primary and future sites are chosen this design can be <br /> completed. There may be more sites available. <br /> The periodically saturated soils were located at 18-30 Inches(mottled soil). Due to the <br /> periodically saturated soits,a pressurized mound system will need to be installed to treat the <br /> septic ef�7uent.The bottom of the treatment area must be located at least 3' above the saturated <br /> soils. <br /> The soils at a depth of 12"have a percolation rate averaging 3 MPI. <br /> A pumping chamber will need to be installed to lift the effluent to the treatment area. The power <br /> supply and switches must be located outside the manhole and pumping chamber in a <br /> weatherproof enclosure. A warning device must be installed with a light and sound device;this is <br /> in case of a pump failure. <br /> Use 7/32 inch uerforations on the laterals. <br /> Keep all heavy equipment off of the proposed treatment areas before and after <br /> construction.The treatment area must be fenced off before construction begins.This Design <br /> is not valid & the System will need to be relocated if failure to protect the areas proposed <br /> for the On-Site Sewage Treatment systems occurs. <br /> Nothing other than gray water,(laundry, showers, ect.)human water&toilet tissue should be <br /> disposed of into the septic tanks. Garbage disposals are not recommended. Additives must not be <br /> used;they may cause harmful damage to your septic system. It is recommended that you pump <br /> the septic tank s every two years. <br /> S�erely, Ci TY OF ��)lZC�N(� <br /> �...��,�._____e_____.. S F:P"I�1 C P E R NI[T 1 L ' : -V E W <br /> �`�� � i�'�SPFCTnR � <br /> �%= JosephJ. Olson [):1TF, -- - PERMITNO. <br /> nr>rriovrn ns s�;�i�n�rr•rro <br /> Q APPROVGD WITH CORREC'TIOti5 AS NOTED <br /> Q NOT APPROVF.[�CORR6C'I'8t RESUBMlT <br /> Thcse commcnts are for your information. AU work sha11 be dase <br /> in full compliance with atl upplicabie septie Qad zoning cudo, <br /> Requircments including items not speciiicelly notect in tbif tCriOw. <br /> KEEP THIS PLAN SBT ON SITE AT ALL TiMF.B <br />