My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
P
>
Pine Ridge Lane
>
2251 Pine Ridge Lane - 34-118-23-22-0022
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:56:24 PM
Creation date
7/5/2018 11:09:11 AM
Metadata
Fields
Template:
x Address Old
House Number
2251
Street Name
Pine Ridge
Street Type
Lane
Address
2251 Pine Ridge Lane
Document Type
Septic
PIN
3411823220022
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO! � O� <br /> Municipal Offices O O <br /> Post Office Box 66 , <br /> Crystal Bay, MN 55323-00�6 � � ON—SITE SEWA(�E TREATI�NT <br /> ,� �, INSPECTION REPORT <br /> ti <br /> II ��`�k'EsH.o�'�G <br /> " ��l �� l2���_ l�.n- <br /> Owner• Address• <br /> Permit #�'s:� Dates: �' Contractors: //hCrbi,r/Y�;�,^ <br /> City ordinance number 100 r�uires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The om site sewage treatm� t system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is � aniexisting system [ ] new construction) <br /> SYSTEM CONFORMITY (7-3): <br /> 1 "CODE SYSTEM"-A syqs em which meets all the Location, design, and construction standards of the current City <br /> Codes, and whiC is operating satisfactorily by treating and disposing of the entire current sewage input <br /> Without dischar ing any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM'-A system which does not meet all the location, design, and construction standards of the <br /> current City C es, but was installed according to the code in effect at the time of installation, and which <br /> is operating s isfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants nto ground or surface waters. <br /> "NON-CONFORMING S1f TEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which mp or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting soil characteristics. <br /> (The limiting 3qtl characteristic [ ] has or�as not been identified at this time. If the limiting soil <br /> characteristic Nas not been identified, this classification may be subject to revision.) <br /> TANK CONDITION (5-10): <br /> Tank inspection indicates: ' <br /> 5 Punpout not needed atlthis time. <br /> 6 Solids accunulation in tanks indicates they should be p�xnped out this year to help prevent future problems. <br /> ,7y 5olids accunulation im tanks is at a critical level. fianks should be punped out as soon as possible. <br /> �� S stem is dischargin 'to the s f ce. Tanks mus within 48 hours <br /> ns ' - an s cou d no in Inspection risers ia. pipe) must be insta ed in each <br /> tank at next pumpout. If tanks have not en punped out uithin the last three years, they should be punped <br /> out now. <br /> 10 inspection pipe is lc}cated directly over tank baffle (does not give acwrate measurement of solids accunulation). <br /> If tanks have nbt been pumped out within the last three years, they should be pumped out now. <br /> DRAINFIELD CONDITION (11-14�: � <br /> Drainfield inspection indi�ates: <br /> 11 Drainfield is dry, no surfacing evident. <br /> � Some evidence of surf cing, not critical yet. <br /> � Drainfield is sature ed and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> imnediately. R�pairs must be completed within 90 days. <br /> 14 Drainffi8t'�"�RLErti'and condition unknown. <br /> L1MITING SITE FACTORS (slope,setbacks.etc.): <br /> POTENTIAL FOR SYSTEM FAILI�f�E (depends on soils,water table,etc.): � <br /> � <br /> OMMENTS: <br /> � w► �e. ' S o �dP,yT( <br /> Date o Inspection eptic y nspector �r ��' <br /> Note: In the event that t �s inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that; this report does not guarantee or certify that an existing system will continue to function <br /> properly� but is merely n opinion of the adequacy of the system under current conditions based on the available <br /> tnformation. <br /> This repoht must be kept on the premises with the system locetion and pumping records. <br /> WWITE COPY/Inspectors File YELLOW COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.