Jesse Struve <br /> From: Jesse Struve <br /> Sent: Thursday, January 03, 2013 2:50 PM <br /> To: Melanie Curtis <br /> Cc: Christine Mattson <br /> Subject: 201301030 2789 Pheasant Rd -2012-01206 <br /> Melanie, <br /> I have reviewed the received on 1/3/13 and do not have any additional comments. Once the full size plans arrive I can <br /> sign off on the permit. <br /> Jesse Struve, PE <br /> Director of Public Works/City Engineer <br /> City of Orono <br /> (952) 249-4661 - Direct <br /> (952) 249-4616- Fax <br /> www.ci.orono.mn.us <br /> From: Jesse Struve <br /> Sent: Monday, December 10, 2012 3:30 PM <br /> To: Melanie Curtis <br /> Cc: Christine Mattson <br /> Subject: 20121210 2789 Pheasant Rd - 2012-01206 <br /> I have reviewed the building permit for a new residential property at 2789 Pheasant Rd and have the following concerns: <br /> • The survey shows a 6" PVC storm pipe extending down the slope ultimately discharging close to the lake. This <br /> would not be allowed without a Conditional Use Permit (CUP). <br /> • Additional grading needs to be shown on the northeast corner of the house to reflect the drainage being <br /> maintained on the existing property. The 948 contour will need to be adjusted and potentially additional survey <br /> will be required to show the proposed grading plan can maintain a swale down this property line. <br /> • I believe the intent of the drainage on the east side of the property is to drain to the low area south of the <br /> house. Has the proposed 6" pipe been designed by a registered professional engineer to make sure it can <br /> handle the runoff from a 100yr event(rainfall or snowmelt)without impacting the proposed structure? This will <br /> need to be signed off by a registered professional engineer. <br /> • The retaining wall on the southwest corner exceeds 4' in height. The applicant will need to submit plans and <br /> specifications from a registered professional engineer for the retaining wall. <br /> • The silt fence shows it is extending significantly into the 0-75' zone. Is it the intent of the applicant to regrade to <br /> install sod or seed? If so this should also be included in the earthwork calculations. If the calculation exceeds 10 <br /> CY, a CUP will be required. <br /> • Are all the easements shown on the survey? Along the north side of the property there is an existing watermain <br /> and sanitary sewer, but no easement is shown. This should be included on the survey. <br /> Jesse Struve, PE <br /> Director of Public Works/City Engineer <br /> City of Orono <br /> (952) 249-4661- Direct <br /> (952) 249-4616- Fax <br /> www.ci.orono.mn.us <br /> i <br />