Laserfiche WebLink
. . <br /> _._ __ . <br /> RHVAC-Residential8�Light Comme�cial HVAC Loads Elite Software Development,inc. <br /> � Pymouth Piumbing&Heating � K.A.WITT-MARTENSON RESIDENCE <br /> Minne�lis,MN 55428-1662 Pa�e� <br /> Total Building Summary Loads <br /> -- ___--- - ------_--____----- -- __--- - -- -- - <br /> Component Area Sen Lat Sen Total� <br /> C Descnption Quan Loss Gain Gain Gain , <br /> ------ ---- .__- - -- -- -- ---- - --- <br /> ', 3D Window Double Pane Low Emit Wood Frame 671 22,286 0 12,078 12,078 <br /> ' 11 C Door Metal Polystyrene Core 84 3,632 0 734 734 ; <br /> ' 121 Wall R-19+ 1/2"Asphit Board(R-1.3) 4321 21,865 0 4,420 4,420 � <br /> ', 15G Wall 5'or More Below Grade 8/12"BIk+R-11 1044 4,129 0 0 0 <br /> ' 161 Ceiling R-44 Insulation 2653 5,614 0 2,380 2,380 <br /> ' 21A Basemt Floor 2'or More Below Grade 2652 5,856 0 0 0 <br /> " Subtotals for structure: 63,382 0 19,612 19,612 ; <br /> ' People: 12 2,760 3,600 6,360 i <br /> ', Equipment: 300 1,200 1,500 ' <br /> ', Lighting: 0 0 0 <br /> '� Ductwork: 16,381 0 0 0 I <br /> ; Infiltration:Winter CFM: 313, Summer CFM: 365 30,734 7,691 5,846 13,537 <br /> ', Ventilation:WinterCFM: 90, SummerCFM: 90 8,837 1,895 1,441 3,336 <br /> ; Sensible Gain Total: 31,699 <br /> � Temperature Swing Multiplier: X 1.15 i <br /> � Total Building Load Totals: 119,334 12,646 36,454 49,100 ; <br /> � Check F' ures <br /> Total Building Supply CFM: 1,882 (1.8 AC/hr) CFM Per Square ft.: 0.271 i <br /> Square ft. of Room Area: 6,956 Square ft. Per Ton: 1,518 j <br /> Building Loads <br /> Total Heating Required With Outside Air. 119,334 Btuh 119.334 MBH ' <br /> i Total Sensible Gain: 36,454 Btuh 74 % ' <br /> j Total Latent Gain: 12,646 Btuh 26 % � <br /> Total Cooling Required With Outside Air. 49,100 Btuh 4.09 Tons(Based On Sensible+ Latent) <br /> 4.58 Tons(Based On 77%Sensible Capacity) � <br /> Notes � <br /> ' Calculations are based on 7th edition of ACCA Manual J. ', <br /> ', All computed results are estimates as building use and weather may vary. � <br /> I Be sure to select a unit that meets both sensible and latent loads. 'I <br />