Laserfiche WebLink
Apr 29 1411:14a Joseph Olson 763-498-8290 p.4 <br /> Property address: 30 Orono Orchard Road, �rorto, MN Inspector initials/Date: J.O.2f25l14 <br /> 4. SOit Sepdr'atyan—Compliance camponent�t4 of 5 <br /> Date of instatlation: 5lQ8/98 ❑Unknown Verification method{s): <br /> ShorelandlWNM�ead probectionl�ood Beverage �Yes �No Soi!o6seiva�ion does not e <br /> i.odging? xpir�.Previous soi! <br /> obseivations by two independerrt parfres ara s�'icient, <br /> ComplianCe criteria: unless site conditions hawe been altered orlocal <br /> For systems built pnor tr�Apri!i, i996, and � ❑Yes ❑No �luirements dffer. <br /> nof located in Shorefand or WeNhead � Conduded soil observa8on(s)(Auadr boring logs) <br /> Prafection Area or not serving a foaof, Q Turo previous verifcations(Attacn boring logs) <br /> beverage orlodging establishmer� <br /> ❑ Not applica�e(hloddir►q ta�rk(s),no ctrain6eld} <br /> Drainfieid has at feast a two-ioot vertipl ❑ Unable to verify(See Comments�xp�a,rarion) <br /> separation distance from periadically <br /> saturated saf a�bedrocic. ❑ Diher(See ComrrrentslFicplana6on) <br /> Non-performance sys[ems builtApri!?, �Yes ❑No CommenfsJExplanafion: <br /> 1998, orfaferorfornon-performance <br /> systems located tn Shareland�r Wellhead <br /> Protection Areas or serving a food, <br /> beverage, orlodging establishmeRt: <br /> Drainfreld has a three�foot vertical <br /> separa6on distance from periodically <br /> saturaied soil or bednodc.* <br /> ExperimentaJ° "Othe�; or °Perfom�ancea ❑Yes ❑No Indicate de hs of elevatfons <br /> sysf�ms built under pr�-2008 Rules Type!V � <br /> or V systems buiJt under 2008 Ru/es(7080. A. BotGom of distribution media 95.7 <br /> 2350or7080.2400 (Advanced Inspedor <br /> LICet15e required) B, Periodical saturabed soiUbedrock 92.9 <br /> Drainfield meets the designed vertical C. S stem se aration 2,8 <br /> separation distanoe from periodically <br /> saturated soi�or 6edrock. <br /> D. R uired cam liance se aration' 2.6 <br /> Any"no"ar�.swer above indicates the system is . <br /> Failing to PrOtect Groundwatel: May be reduoed up io 15 percent if allowed by Locaf <br /> OMina nce. <br /> 5. OperaNng Permit and Nitrogen BMP'�—comp�ianoe component�of 5 �Not applicable <br /> Is the system operated under an Operating Permit7 ❑Yes ❑ No If"yes",A below is required <br /> Is the system required to empby a Nidrogen BMP? ❑Yes ❑No If"yes",6 below is required <br /> BMP=Best Management Practice(s)specified in fhe system design <br /> !f the answ+er to both questions is "rro", ifiis sectPon does not need to be completed. <br /> Com liance criteria <br /> a. OperaSng Permit number: <br /> Have the O rati Permit re uirements been met? ❑Yes ❑ No <br /> b. is the uired n�tro err BMEP in lace a�d ro erl func3ionin ? ❑Yes No <br /> Any "no�answer irt�cafes Nancompliance. <br /> Upgrede Requirements(�nn_SYaf§115.55)An imminent threet fo�c health and safety(iTPHS)must be upg�raded,replaced,or its use <br /> discoMinued wifhin ten months of recerpt of this rrotice or within a sho►ter perrod if required by loca!ordinance.If the system is faiting to protect <br /> groemd water,ri►e system must be upc�raded,r+epJaced,or its use disoartinued within the�ime riequirad by bca!avi7irmrace.lf sn existing system <br /> is not fatling as delined in law,anci hss at least two feet of design�il separdtion,then the system need not be upgraded,rspaired,replac�d,or <br /> �ts use drscontinued,notwiihstandenq any loca!adfnance fhat is more�.This provision does rwf apply to systems in shoreland areas, <br /> WelHtead Protection Ansas,or fhose used in connection with fooQ,beverage,ar►tJ lodging establishments as defr►ted rn faer. <br /> www.pca.sCate.mn.us • 651-Z96-6300 • 800-657-3864 • TTY 651•282-5332 or 800-657-3864 • Available a�altemative formats <br /> wq-wwists4-3J • i/24l!2 <br /> Page 3 of 3 <br />