My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info including future design
Orono
>
Property Files
>
Street Address
>
O
>
Orono Orchard Road North
>
030 Orono Orchard Road North - 35-118-23-33-0037
>
Septic
>
septic info including future design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:58:42 PM
Creation date
6/6/2018 12:08:50 PM
Metadata
Fields
Template:
x Address Old
House Number
30
Street Name
Orono Orchard
Street Type
Road
Street Direction
North
Address
30 Orono Orchard Road North
Document Type
Septic
PIN
3511823330037
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Apr 29 1411:14a Joseph Olson 763-498-8290 p.4 <br /> Property address: 30 Orono Orchard Road, �rorto, MN Inspector initials/Date: J.O.2f25l14 <br /> 4. SOit Sepdr'atyan—Compliance camponent�t4 of 5 <br /> Date of instatlation: 5lQ8/98 ❑Unknown Verification method{s): <br /> ShorelandlWNM�ead probectionl�ood Beverage �Yes �No Soi!o6seiva�ion does not e <br /> i.odging? xpir�.Previous soi! <br /> obseivations by two independerrt parfres ara s�'icient, <br /> ComplianCe criteria: unless site conditions hawe been altered orlocal <br /> For systems built pnor tr�Apri!i, i996, and � ❑Yes ❑No �luirements dffer. <br /> nof located in Shorefand or WeNhead � Conduded soil observa8on(s)(Auadr boring logs) <br /> Prafection Area or not serving a foaof, Q Turo previous verifcations(Attacn boring logs) <br /> beverage orlodging establishmer� <br /> ❑ Not applica�e(hloddir►q ta�rk(s),no ctrain6eld} <br /> Drainfieid has at feast a two-ioot vertipl ❑ Unable to verify(See Comments�xp�a,rarion) <br /> separation distance from periadically <br /> saturated saf a�bedrocic. ❑ Diher(See ComrrrentslFicplana6on) <br /> Non-performance sys[ems builtApri!?, �Yes ❑No CommenfsJExplanafion: <br /> 1998, orfaferorfornon-performance <br /> systems located tn Shareland�r Wellhead <br /> Protection Areas or serving a food, <br /> beverage, orlodging establishmeRt: <br /> Drainfreld has a three�foot vertical <br /> separa6on distance from periodically <br /> saturaied soil or bednodc.* <br /> ExperimentaJ° "Othe�; or °Perfom�ancea ❑Yes ❑No Indicate de hs of elevatfons <br /> sysf�ms built under pr�-2008 Rules Type!V � <br /> or V systems buiJt under 2008 Ru/es(7080. A. BotGom of distribution media 95.7 <br /> 2350or7080.2400 (Advanced Inspedor <br /> LICet15e required) B, Periodical saturabed soiUbedrock 92.9 <br /> Drainfield meets the designed vertical C. S stem se aration 2,8 <br /> separation distanoe from periodically <br /> saturated soi�or 6edrock. <br /> D. R uired cam liance se aration' 2.6 <br /> Any"no"ar�.swer above indicates the system is . <br /> Failing to PrOtect Groundwatel: May be reduoed up io 15 percent if allowed by Locaf <br /> OMina nce. <br /> 5. OperaNng Permit and Nitrogen BMP'�—comp�ianoe component�of 5 �Not applicable <br /> Is the system operated under an Operating Permit7 ❑Yes ❑ No If"yes",A below is required <br /> Is the system required to empby a Nidrogen BMP? ❑Yes ❑No If"yes",6 below is required <br /> BMP=Best Management Practice(s)specified in fhe system design <br /> !f the answ+er to both questions is "rro", ifiis sectPon does not need to be completed. <br /> Com liance criteria <br /> a. OperaSng Permit number: <br /> Have the O rati Permit re uirements been met? ❑Yes ❑ No <br /> b. is the uired n�tro err BMEP in lace a�d ro erl func3ionin ? ❑Yes No <br /> Any "no�answer irt�cafes Nancompliance. <br /> Upgrede Requirements(�nn_SYaf§115.55)An imminent threet fo�c health and safety(iTPHS)must be upg�raded,replaced,or its use <br /> discoMinued wifhin ten months of recerpt of this rrotice or within a sho►ter perrod if required by loca!ordinance.If the system is faiting to protect <br /> groemd water,ri►e system must be upc�raded,r+epJaced,or its use disoartinued within the�ime riequirad by bca!avi7irmrace.lf sn existing system <br /> is not fatling as delined in law,anci hss at least two feet of design�il separdtion,then the system need not be upgraded,rspaired,replac�d,or <br /> �ts use drscontinued,notwiihstandenq any loca!adfnance fhat is more�.This provision does rwf apply to systems in shoreland areas, <br /> WelHtead Protection Ansas,or fhose used in connection with fooQ,beverage,ar►tJ lodging establishments as defr►ted rn faer. <br /> www.pca.sCate.mn.us • 651-Z96-6300 • 800-657-3864 • TTY 651•282-5332 or 800-657-3864 • Available a�altemative formats <br /> wq-wwists4-3J • i/24l!2 <br /> Page 3 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.