My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info including future design
Orono
>
Property Files
>
Street Address
>
O
>
Orono Orchard Road North
>
030 Orono Orchard Road North - 35-118-23-33-0037
>
Septic
>
septic info including future design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:58:42 PM
Creation date
6/6/2018 12:08:50 PM
Metadata
Fields
Template:
x Address Old
House Number
30
Street Name
Orono Orchard
Street Type
Road
Street Direction
North
Address
30 Orono Orchard Road North
Document Type
Septic
PIN
3511823330037
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br /> 2250 gallon Septic tank (minimum) Tank options: none <br /> �ux �arger �anK wi�n rnuiupie compi[.anKs <br /> 750 gallon Dose tank (minimum) at �gpi <br /> 36 GPM C� ##### ft. of head, Pump required <br /> ######inch swing on Demand float which transtates to roughly ##### inches of float tether length <br /> if time dosing is required --> ##### minutes ON time£t ##### hours OFF time <br /> ###### inches from bottom of tank to "pump ON"float, or 12 inches to"timer ON"float <br /> ###### inches from bottom of tank to "Hi Level Alarm"or ##### inches to"Hi level alarm" if time dosed <br /> �ft. of 2.0 inch supply line with end feed manifold connection <br /> (Tip: "top feed" manifold to controt drainback} <br /> 18 inch, or 1.5 ft. Sand Lift Mound <br /> 10.0 ft. wide by 63.0 ft. long Rock bed <br /> 3 laterals 2.00 inch diameter 61.0 ft. tong 3.0 ft. lateral spacing <br /> 7/32 inch perfs 3.0 ft. perforation spacing <br /> No Effluent filter 8 alarm <br /> 3 ctean out tt valve box assemblies <br /> 20.0 ft.Total sand ABSORPTION width (minimum) <br /> 0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br /> 10.0 ft. Downslope (sand beyond rockbed, minimum) <br /> Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br /> 4:1 upslope ratio 10 ft. upslope berm <br /> 3:1 sideslope 14 ft. sideslope berms <br /> 3:1 downslope 20 ft. downslope berm <br /> 4" inspection pipe <br /> 18" cover on top <br /> U slo e berm �� Downsla e berm Z� <br /> 12" cover on sides <br /> —�` (6"loamy cap&6"topsoily <br /> 1.5 , Ctean sand ;ift ''�-�.�,, <br /> — � 1.5 Depth t� _�n�atiri� <br /> _�__ <br /> —_�___._._ <br /> �i�nitir�� ;�unclittor ^` — `�— --- —-- __ ____ ___ <br /> • 20.0 —._ <br /> pbsQr tion Width �--'__ ---- __ _. _ _. _ ____ — <br /> Note: <br /> For 0 to 1�slopes, Absorptron W/dth is measured from the Bedequally in b�oth d�reckions. <br /> For slopes >1�, .4Gsorptron Wldth is measured dawnhitl fram the upslope ed�e vf the Bed. <br /> Rock Bed: 21.0 yd3 or'1.4= 29 ton 6 inches under pipe <br /> Mound Sand: 205 yd3 or"1•4= 286 ton calculation based on 3:1/4:1 slope from top of rockbe� <br /> Loamy Cap: 70 yd3 or`1.4= 98 ton 6"deep <br /> Topsoil: 81 yd3 or"1.4= 113 ton b"deep <br />