Laserfiche WebLink
On the North Shore o f <br /> Lake Minnetonka <br /> ON-SITE SEWAGE TREATMENT <br /> INSPECTION REPORT � POST OFFICE BOX 66 <br /> 1335 S. Brown Rd. <br /> • � � � Crystal Bay, MN 55323 <br /> 473-7357 <br /> OWNER / , �nn�5�� �-J ADDRESS �/S C/X�T�i'L7 FL4i <br /> PERMIT NO.'S. DATES � - . -� CONTRACTORS � � <br /> . <br /> City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage <br /> treatment system at the above address has been inspected and appears to fall into the category checked below. <br /> IThis is � an existing system ❑ new construction) <br /> � � Meets or exceeds current City standards in all respects relating to design,construction,and locetion.Appears to be operating <br /> properly. <br /> � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, <br /> located, and constructed generaliy in accordance with previous codes.System appears to be functioning properly;no major <br /> upgrading of the system is required at this time. <br /> � 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating <br /> adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at <br /> this time. <br /> � 4 System may or may not meet current City atandards for design,construction or tocation, but is failing to properly treat and <br /> dispose of the current input,and is e�dangering a water supply,or is a source of pollution to surface or groundwaters,or is <br /> creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ <br /> replacement procedures. If drainfield replacement is necesaary,soil testing will usually be required,and a design and site plan <br /> must be submitted for review.Your contractor must obtain a permit before work is started. <br /> SYSTEM CONDITION (m Checked items may require your action) <br /> Tank inspection indicetes: ❑ Inspection pipe is located directly over tank beffle.(Does not <br /> ❑ Pumpout not needed at this time. give accurate measurement of solids accumulatio�.) If tanks <br /> ❑ Solids eccumulation in tenks indicates they should be pump. have not been pumped out within the last three years,they <br /> ed out this year to help prevent future problems. should be pumped out now. <br /> ❑ Solids accumulation in tanks ia at a critical level. Tanks Drain ield inspection indicates: <br /> should be pumped out as soon as possible. �Drainfield is dry,no surfacing evident. <br /> ❑ System is discharging to surface. Tanks must be pumped � Some eviden�of surfacing,not critical yet. <br /> within 48 hours to eliminate surface discharge. ❑ Drainfield is satureted and visibly discharging untreated <br /> �Inspection risera missing—tanks could not be inspected, effluent to the surface. This condition may require replace- <br /> Inspection risera (4"dia.pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector <br /> at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. <br /> the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown, <br /> SITE CHARACTERISTICS: <br /> Limiting Site Factors Pote�tial for System Failure Site Capabilities for <br /> ❑ Slope (�pends on soil types,water Futu e Expansion <br /> ❑ oil table,and system condition) Adequate <br /> �HHigh water table q Low air <br /> ❑ Lot size ��..NAedium ❑Poor <br /> ❑ Lake,wetland,or stream ❑ High ❑ Inadequate <br /> ❑ Drainage ❑System is causing visible <br /> surface discharge. <br /> COMMENTS: <br /> �=��9f <br /> Date of Inspection eptic Syst m Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that <br /> this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opi�ion of the adequacy <br /> of the system under current conditions based on the available information. <br /> This report must be kept on the premises with system location and pumping records. <br /> WHITE COPY/Inspector's File GOLD COPY/Homeowner <br />