My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info (2)
Orono
>
Property Files
>
Street Address
>
O
>
Orono Orchard Rd S
>
485 Orono Orchard Road South - 02-117-23-32-0001
>
Septic
>
septic info (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:09:06 PM
Creation date
5/23/2018 8:09:56 AM
Metadata
Fields
Template:
x Address Old
House Number
485
Street Name
Orono Orchard
Street Type
Road
Street Direction
South
Address
485 Orono Orchard Rd S
Document Type
Septic
PIN
0211723320001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO O `V <br /> Municipal Offices #t, <br /> Post Office Box 66 ; i0. <br /> Crystal Bay, MN 55323-0066 P ON—SITE SEWAGE TREATMENT <br /> A14,6Z-.�',�1 �IT'' INSPECTION REPORT <br /> 41. iliiiP 4" <br /> k'EsBo <br /> Owner: TAA Jar [ 11-017717-\ Address: `7 1 (JY017D (1226,, Po/S• <br /> Permit #'s: Dom- Dates: 13-12S`-g) Contractors: E. J i/S�TiP,fSDJ• a <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is (*an existing system I ) new construction) <br /> SYSTEM CONFORMITY (1-3): a <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> © ground pollutants into or surface waters. <br /> "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting soil characteristics. <br /> (The limiting soil characteristic ( I has or has not been identified at this time. If the limiting soil <br /> characteristic has not been identified, this c assification may be subject to revision.) <br /> TANK CONDITION (5-10): ja <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. <br /> 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each <br /> tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped <br /> out now. <br /> Inspection pipe is located directlyover tank baffle (does not give accurate measurement of solids accumulation). <br /> If tanks have not been pumped out within the last three years, they should be pumped out now. <br /> DRAINFIELD CONDITION (11-14): 1 <br /> Drainfield inspection indicates: <br /> 11 Drainfietd is dry, no surfacing evident. <br /> a <br /> Some evidence ofsurfacing, notcriticalyet.Drainfietd is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfietd extent and condition unknown. <br /> LIMITING SITE FACTORS (slope.setbacks.etc.): <br /> POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table etc.): _l J <br /> COMMENTS EV <br /> rA 1 fZs t W. ►ii - re "A6.e__- // ► !.' f'/I!/i"c' _.O.t / Cif �1GI. <br /> Date of Inspection tic S s em Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly, but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> information. <br /> This report must be kept on the premises with the system location and pumping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.