Laserfiche WebLink
RIGHT-J LOAD AND EQUIPMENT SUMMARY <br /> 6-2-00 <br /> For: GARNETT <br /> SYSTEM #2 <br /> By: CONWAY MECHANICAL <br /> Job #: <br /> Wthr : Minneapolis/St ._Paul AP MN <br /> Zone : <br /> WINTER DESIGN CONDITIONS SUMMER DESIGN CONDITIONS <br /> Outside db: -12 Deg F Outside db: 90 Deg F <br /> Inside db: 70 Deg F Inside db: 72 Deg F <br /> Design TD: 82 Deg F Design TD: 18 Deg F <br /> Daily Range M <br /> Rel . Hum. : 50 % <br /> Grains Water 33 gr <br /> HEATING SUMMARY SENSIBLE COOLING EQUIP LOAD SIZING <br /> Bldg. Heat Loss 84894 Btuh Structure 62810 Btuh <br /> Ventilation Air 200 CFM Ventilation 1980 Btuh <br /> Vent Air Loss 18040 Btuh Design Temp. Swing 3 . 0 Deg F <br /> Design Heat Load 102934 Btuh Use Mfg. Data n <br /> Rate/Swing Mult . 0 . 95 <br /> Total Sens Equip Load 61550 Btuh <br /> INFILTRATION LATENT COOLING EQUIP LOAD SIZING <br /> Const Qual b # Fireplaces 2 Internal Gains 2300 Btuh <br /> Ventilation 2244 Btuh <br /> HEATING COOLING Infiltration 3697 Btuh <br /> Area (sq. ft . ) 4275 4275 Tot Latent Equip Load 8241 Btuh <br /> Volume (cu. ft . ) 49320 49320 <br /> Air Changes/Hour 0 . 5 0 .2 Total Equip Load 69791 Btuh <br /> Equivalent CFM 412 165 <br /> HEATING EQUIPMENT SUMMARY COOLING EQUIPMENT SUMMARY <br /> Make BRYANT Make JANITROL <br /> Model 350MAV060120 Model CK-60-1 <br /> Type Type <br /> Efficiency / HSPF 92 . 0 COP/EER/SEER 10 . 0 <br /> Heating Input 120000 Btuh Sensible Cooling 0 Btuh <br /> Heating Output 110000 Btuh Latent Cooling 0 Btuh <br /> Heating Temp Rise 63 Deg F Total Cooling 0 Btuh <br /> Actual Heating Fan 1600 CFM Actual Cooling Fan 2000 CFM <br /> Htg Air Flow Factor 0 . 019 CFM/Btuh Clg Air Flow Factor 0 . 032 CFM/Btuh <br /> Space Thermostat Load Sens Heat Ratio 91 <br />