My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
O
>
Orono Orchard Rd S
>
100 Orono Orchard Road South - 02-117-23-21-0032
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:07:21 PM
Creation date
5/18/2018 12:13:56 PM
Metadata
Fields
Template:
x Address Old
House Number
100
Street Name
Orono Orchard
Street Type
Road
Street Direction
South
Address
100 Orono Orchard Rd S
Document Type
Septic
PIN
0211723210032
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
°� <br /> r0 0 <br /> CITY of ORONO <br /> 1` " ,��,// <br /> Municipal Offices <br /> \'�* r G gSol-x49-'160 qMailing <br /> Street Address: Address: <br /> - pg' <br /> �-:W� 2750 Kelley Parkway P.O. Box 66 <br /> ._ ESI; <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: 10 0 0(0 r\O 0 1 clArd 1U. -S <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): 3 <br /> 1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISIS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> 3y <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): <br /> Tank inspection indicates: - <br /> 0 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ). <br /> Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper <br /> cleaning. Keep water softner and iron filter discharge out of septic system to prolong life of drainfield. Ask pumper to test <br /> alarm float to verify alarm is still working in your house. The alarm warns owner that septage is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If . <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> e , I MLD CONDITION(8-10): S( <br /> 49 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: Y(ti>��- t\� ro�-car-p\;( ,e,5-- a-- 0-A0-A,58__ kv3� cc r,��J <br /> ,-.\-7. st,...tr ). , vz.=11-2_01 x , <br /> -1-1--01"\ G1( C Airti , <br /> Date of Inspection Matt Bolterman- Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does <br /> not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available information. <br />
The URL can be used to link to this page
Your browser does not support the video tag.