Laserfiche WebLink
(:10------)0---":111, <br /> = CITY of ORONO <br /> 11+ <br /> 1 j r Av Municipal <br /> ,d 4 ,� Offices,�'; 'ryG Street Address: Mailing Address: <br /> ' 'Lgg04' 2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: Qi-Ael,) iti—e,1 kirj Address: 105 Orono Orchard- Rd. N. <br /> Permit #'s: 121 Dates: B/31/87 Contractors: E. J. Peterson Co. <br /> (This is [),(] an existing system [ ] new construction) . <br /> OSTEM COMPLIANCE (1-3) : 1 <br /> Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears t be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> 3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system With less than three feet of vertical separation between the bottom <br /> of the drainfield and the saturated soil level. <br /> (The saturated soil level is [ or is not [ ] identified under this septic system. If the <br /> saturated soil level is not dentified, this classification is subject to revision.) <br /> cirCONDITION (5-9) : 5 <br /> Pumpout not needed at t is time. <br /> Solids accumulation in .anks indicates they should be pumped out this year. <br /> 7 System is discharging t. the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missi g-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, the should be pumped out and risers installed now. <br /> 9 Inspection pipe is loca.ed over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped ou within three years, they should be pumped out now. <br /> 10 One or more tanks are c=sspools, which means the septic system is non-compliant. <br /> (The tanks are [ ] or are no [ ] water tight or the condition is '>, unknown. If the tanks <br /> are not confirmed to be water ight, this classification is subject to revision.) <br /> OAINFIELD CONDITION (11-14) : 11 <br /> Drainfield is dry, no su facing evident. <br /> 12 Some evidence of surfaci g, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturate. and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspect.r immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and co dition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: I (system age and condition, soils, etc.) : low <br /> COMMENTS: In order to confir0 that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a foot separation between the drainfield and the seasonal water <br /> table. The separation is 3 feet and the system is compliant. <br /> / <br /> 1� QQ <br /> 7T!v /n _! 4 / JIII1I1 <br /> Date of Inspecti.n Se! is System nspect.r <br /> Note: In the event that th's inspection report is used to satisfy the requirements for a <br /> transfer of property, this re ort does not guarantee that an existing system will continue to <br /> function properly, but indicat s the operation of the system under current conditions. <br /> k'elephone (612) 473-7357 • FAX 473-0510 <br />