On the North Shore of <br /> Lake Minnetonka <br /> ON-SITE SE AGE TREATMENT CITY <br /> INSPEC ION REPORT OF POST OFFICE BOX 66 <br /> O R O N O 1335 S. Brown Rd. <br /> Crystal Bay, MN 55323 <br /> 473-7357 <br /> OWNER \. 44) 1)-. C1YY1P{' ADDRESS CPS- (71C4,,d DliGhiiri 1QG'/ it/ <br /> PERMIT NO.'S. -S-0/7 DATES 11-- /-77 CONTRACTORS .cAr„e, -C-4,77.-4— <br /> City <br /> c-4City Ordina ce No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage <br /> treatment system a the above address has been inspected and appears to fall into the category checked below. <br /> (T is is Cig an existing system 0 new construction) <br /> MI1 M-:is or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating <br /> pr.perly. <br /> 2 D..s not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, <br /> to ted, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major <br /> u., ading of the system is required at this time. <br /> 0 3 D..s not meet current City standards in many respects relating to design,construction,or location.Appears to be operating <br /> ade•uately at this time,but has a relatively high potential for future problems. No major upgrading of system is required at <br /> this time. <br /> El4 Sys =m may or may not meet current City standards for design,construction or location,but is failing to properly treat and <br /> dis••se of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is <br /> crea ing a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ <br /> repl ment procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan <br /> mus be submitted for review.Your contractor must obtain a permit before work is started. <br /> SYSTEM CONDITIO ( m Checked items may require your action) <br /> Tank inspection indi tes: 0 Inspection pipe is located directly over tank baffle.(Does not <br /> aPumpout not :-dad at this time. give accurate measurement of solids accumulation.) If tanks <br /> Solids accumul tion in tanks indicates they should be pump- have not been pumped out within the last three years,they <br /> ed out this yea to help prevent future problems. should be pumped out now. <br /> ❑ Solids accumu ation in tanks is at a critical level. Tanks Drainfield inspection indicates: <br /> should be pum•-d out as soon as possible. VI Drainfield is dry,no surfacing evident. <br /> ❑ System is disc arging to surface. Tanks must be pumped 0 Some evidence of surfacing,not critical yet. <br /> within 48 hours to eliminate surface discharge. 0 Drainfield is saturated and visibly discharging untreated <br /> ❑ Inspection rise missing—tanks could not be inspected, effluent to the surface. This condition may require replace- <br /> Inspection riser (4"dia.pipe)must be installed in each tank ment or additions to dreinfield. Contact the City Inspector <br /> at next pumpo t. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. <br /> the last three ye rs,they should be pumped out now. 0 Drainfield extent and condition unknown. <br /> SITE CHARACTER IS ICS: <br /> Limiting Site Factors Potential for System Failure Site Capabilities for <br /> ❑ Slope (depends on soil types,water Future Expansion <br /> ❑ Soil table,and system condition) 0 Adequate <br /> ❑ High water table ig Low 0-Fair <br /> ❑ Lot size 0 Medium 0 Poor <br /> ❑ Lake,wetland,o stream 0 High 0 Inadequate <br /> ❑ Drainage 0 System is causing visible <br /> surface discharge. <br /> COMMENTS: <br /> 4.. 2221 <br /> Date of Inspection S tic System Inspector <br /> Note: In the event that . is inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that <br /> this report does not guar:ntee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy <br /> of the system under curre t conditions based on the available information. <br /> This report must be kept on the premises with system location and pumping records. <br /> WHITE COPY/Inspector's File GOLD COPY/Homeowner <br />