Laserfiche WebLink
O i O <br /> =,.a CITY of ORONO <br /> 4°1 <br /> })1 f t Municipal Offices <br /> �.- 1 �� <br /> 'i ry Street Address: Mailing Address: <br /> H04' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: I .L <br /> ! eib <br /> Address: 25 Orono Orchard Rd. N. <br /> Permit #'s: 50107 Dates: 11/21/77 Contractors: Steve Schmit <br /> (This is 0(1 ahexistingsystem [ ] new construction) . <br /> SYSTEM COMPLIANC (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> constructio , and location. Appears to be operating properly. <br /> 2 Compliant S stem: Does not meet all current City standards for new construction, but in <br /> most respec s appears to be designed, located, and constructed in accordance with previous <br /> 03 codes and i functioning properly. <br /> Non-Compli t System: System may or may not meet current City standards for design, <br /> constructioor , or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom <br /> . of the drainfield and the saturated soil level. <br /> II <br /> (The saturated soil level is [ or is not [ I identified under this septic system. If the <br /> saturated soil lural is not identified, this classification is subject to revision.) <br /> CONDITION (59) : 5 <br /> 0 Pumpout not needed at this time. <br /> . Solids accumi4lation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection r sers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three ears, they should be pumped out and risers installed now. <br /> 9 Inspection pi a is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanks are [ or are not [ ] water tight or the condition is [ ] unknown. If the tanks <br /> are not confirmed t o be watertight, this classification is subject t revision.) <br /> 1 <br /> INFIELD CONDITI N (11-14) : 11 <br /> Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield ext nt and condition unknown. <br /> POTENTIAL FOR SYSTE1k1 FAILURE: (system age and condition, soils, etc.) : medium <br /> l <br /> COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to erify a 3 foot separation between the drainfield and the seasonal water <br /> table. The separat on is 0 feet and the system is non-compliant. Repair or replacement of the <br /> septic system is re fired by 12/31/2008. <br /> 7.-',P.,5 <br /> Date of Inspe tion Sep c System Inspector <br /> Note: In the even that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, b t indicates the operation of the system under current conditions. <br /> it <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />