My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
O
>
Orono Oaks Drive
>
1350 Orono Oaks Drive - 35-118-23-34-0006
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:58:52 PM
Creation date
5/4/2018 12:35:02 PM
Metadata
Fields
Template:
x Address Old
House Number
1350
Street Name
Orono Oaks
Street Type
Drive
Address
1350 Orono Oaks Drive
Document Type
Septic
PIN
3511823340006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I0 <br /> ( OC \ <br /> .--... , <br /> ___.,.,„,, ,,, 1,N,13.., „, <br /> CITYofORONO <br /> vivet,.. �, ,, �y l4 Municipal Offices <br /> t VY1 -�tit¢ Street Address: Mailing Address: <br /> rem 2750"emlleNy Parkway P.O. Box 66 <br /> Orono55356 Crystal Bay, MN 55323.0066 <br /> Owner: James Pal mer Address: 1350 Orono Oaks Dr. <br /> Permit #'s: 5569 Dates: 5/24/79 Contractors: Westonka Plbg. <br /> (This is [ ] an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System- Does not meet all current City standards for new construction, but in <br /> most respects ap ears to be designed, located, and constructed in accordance with previous <br /> codes and is fun tioning properly. <br /> 3 Non-Compliant S tem: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any s stem with less than three feet of vertical separation between the bottom <br /> of the drainfiel and the saturated soil level. <br /> (The saturated soil level is [ ] or is not [ ] identified under this septic system. If the <br /> saturated soil level is not identified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 8 <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been p ed out within three years, they should be pumped out now. <br /> 10 The tank or tanks meet the definition of a cesspool and must be replaced within 10 months. <br /> (The tanks are [ ] or are not [ ] water tight or the condition is [ ] unknown. If the tanks <br /> are not confirmed to ba watertight, this classification is subject to revision.) <br /> DRAINFIELD CONDITION (_1-14) : 11 <br /> 11 Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of Surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is s4turated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extentland condition unknown. <br /> POTENTIAL FOR SYSTEM FJ.ILURE: (system age and condition, soils, etc.) : medium <br /> COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water <br /> table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the <br /> septic system is required by 12/31/2008. <br /> 4/16/98 �1 .��T�ih(,Ct,17 O <br /> Date of Inspection Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> I <br /> 1 Telephone (612) 473-7357 • FAX 473-0510 <br />