My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2013-00100 - new structure
Orono
>
Property Files
>
Street Address
>
O
>
Orchard Park Road
>
665 Orchard Park Road - 31-118-23-11-0005
>
Permits/Inspections
>
2013-00100 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:28:24 PM
Creation date
4/30/2018 3:15:04 PM
Metadata
Fields
Template:
x Address Old
House Number
665
Street Name
Orchard Park
Street Type
Road
Address
665 Orchard Park Road
Document Type
Permits/Inspections
PIN
3111823110005
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
p(l o,' 5 eev <br /> Exhibit M: New Construction Energy Code Compliance Certificate <br /> Per N1101.8 Building Certificate.A building certificate shall be posted in a permanently visible location Date 1 2/5/20131 <br /> inside the building. The certificate shall be completed by the builder and shall list information and values <br /> of components listed in Table N1101.8. <br /> Mailing Address of the Dwelling or Dwelling Unit City S <br /> 665 Orchard Park Rd. Orono .,�..„,,.,. . . .,. <br /> Name of Residmfiel Cmtractor MN Lionise Number <br /> Systems Built, Inc., d.b.a. Suncrest Builders BC636167 <br /> THERMAL ENVELOPE RADON SYSTEM <br /> Type:Check All That Apply X Passive(No Fan) <br /> Total R- Active(With fan and monometer <br /> Value of or other system monitoring device) <br /> all Types <br /> Insulation Location of <br /> Insulation NA Fib Fibt Foan Foat Mir Rigi Rigic Other Please Describe Here <br /> Below Entire Slab X <br /> Foundation Wall X Exterior <br /> Perimeter of Slab on Grade X <br /> Rim Joist(Foundation) X interior <br /> Rim Joist(1st Floor'-) X <br /> Wall X <br /> ceiling,fiat X <br /> Ceiling,vaulted X <br /> Bay Windows or cantilevered areas X <br /> Bonus mom over garage X <br /> Describe other insulated areas <br /> Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces <br /> Average U-Factor(excludes skylights and one door)U: 0.32 Not applicable,all ducts located in conditioned space <br /> Solar Heat Gain Coefficient(SHGC): 0.28 R-value <br /> MECHANICAL SYSTEMS Make-up Alr Select a Type <br /> Appliances Heating System Domestic Water Heater Cooling System Not required per mech.code <br /> Fuel Type Geothermal Nat. Gas Geothermal X Passive <br /> Manufacturer Water Furnace A.O. Smith Water Furnace Powered <br /> Interlocked with exhaust device. <br /> Model TBD TBD TBD Describe: <br /> Input in Capacity Output in Other,describe: <br /> BTUS: in Gallons: Tons: <br /> Rating or Size <br /> Heat Loss: 54300 Heat Gain: 31600 Location of duct or system: <br /> Structure's Calculated <br /> AFUE or SEER: 21 <br /> HSPF% <br /> 4.1 Calculated <br /> cooling load: 31600 <br /> Efficiency Cfm's <br /> "round duct OR <br /> Mechanical Ventilation System "metal duct <br /> Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type <br /> source heat pump with gas back-up furnace): Not required per mech.code <br /> Select Type X Passive <br /> X Heat Recover Ventilator(HRV) Capacity in cfms: Low: 67 High: 137 Other,describe: <br /> Energy Recover Ventilator(ERV)Capacity in cfms: Low: High: Location of duct or system <br /> Continuous exhausting fan(s)rated capacity in cfms: <br /> Location of fan(s),describe: Cfm's <br /> Capacity continuous ventilation rate in cfms: "round duct OR <br /> "metal duct <br /> Total ventilation(intermittent+continuous)rate in cfms: <br />