2010-00482 - new septic
Orono
>
Property Files
>
Street Address
>
O
>
Orchard Park Road
>
615 Orchard Park Road - 31-118-23-11-0006
>
Septic
>
2010-00482 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:28:29 PM
Creation date
4/30/2018 1:10:05 PM
Metadata
Fields
Template:
x Address Old
House Number
615
Street Name
Orchard Park
Street Type
Road
Address
615 Orchard Park Road
Document Type
Septic
PIN
3111823110006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> Rusty Olson's--Soil and Percolation Testing <br /> Joseph J. Olson--MPCA License#810 <br /> 11481 Riverview Rd. NE,Hanover,MN 55341 <br /> (763)498-8779 Fax(763)498-8290 <br /> November 23,2009 ell-C110 COQ <br /> Kevin Lang <br /> 615 Orchard Park Road <br /> Orono,Hennepin County <br /> This on-site Sewage Treatment System is designed for a Type 1 three-bedroom home in accordance with <br /> the Minnesota Pollution Control Agency Chapter 7080 and local ordinances. <br /> The periodically saturated soils were located at 12"-22"(mottled soil).Due to the periodically saturated <br /> soils,a pressurized mound system will need to be installed to treat the septic effluent.The bottom of the <br /> treatment area must be located at least 3'above the saturated soils. <br /> All neighboring wells are greater than 100 feet from proposed treatment areas. <br /> The soils at a depth of 12"have a percolation rate averaging 6 MPI. <br /> O <br /> The existing septic system does not conform to the state code chapter 7080. CO?). <br /> The existing tank must be abandoned. <br /> All new tanks need to be insulated if there is less than two feet of cover over the top of the tanks and a filter <br /> installed on the second tank.Clean outs must be installed on the end of the laterals for maintenance. <br /> A pumping chamber will need to be installed to lift the effluent to the treatment area. The power supply and <br /> switches must be located outside the manhole and pumping chamber in a weatherproof enclosure. A <br /> warning device must be installed with light and sound devices;this is in case of a pump failure.The <br /> manifold and supply line must have back drainage to the pump chamber.The rock and fill materials must <br /> be clean.The sod layer below the entire mounded area must be turned over.Just break up the sod and be <br /> sure not to over work. <br /> Nothing other than gray water,(laundry,showers,etc.) Human water and toilet tissue should be <br /> disposed of into the septic tanks. Garbage disposals are not recommended. Additives must not be <br /> used;they may cause harmful damage to your septic system. It is recommended that you pump the <br /> tank every year for 1 tank,every two years for two tanks. <br /> erely, <br /> Creel,ORONO <br /> Joseph J.Olsonp� 1 11 <br /> DAT - PERMIT <br /> Ci/MC)COPY APPROVED AS I►t RVITTED <br /> �] APPROVED WITH CORRECTIONS AS NOTED <br /> Q NOT APPROVED-CORRECT&RESUBMIT <br /> These comments arc for your information. All work shall he done <br /> in tall compliance with all applicable septic and lolling code. <br /> Rco,+ircn:ents including hello no+specifica''ly noted at this review. <br /> IvLLP THIS PLAN SEI ON SI TL \T ALL I IM' <br />