Laserfiche WebLink
Rhvac-Residential 8 Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Riccar Heating and CoolingIlk TJB-393 Mallak <br /> Andover,MN 55304 <br /> Page 2 <br /> Total Building Summary Loads <br /> 'C60ponerite 4 ti • t •,£ 't•• , k , 1 ���';9rea 3 Seng bi l Sen 3°� o._1 <br /> -�o ii Y{ s �. ,q ri,il r t - ai , G . <br /> De�cnl�log t . : � r.,. .. a ��. . i+.,-i n , k' ., 4��(swan : Loss' . - �. cpm �. � . +Galn� �4► i. <br /> Andersen: Glazing-operable window,wood sash, u-value 531.3 13,105 0 16,951 16,951 <br /> 0.29, SHGC 0.32 <br /> 10D-f: Glazing-French door, double pane low-e glass(e= 44.4 1,585 0 686 686 <br /> 0.10), insulated fiberglass frame, u-value 0.42, <br /> SHGC 0.32 <br /> Andersen: Glazing-operable window,wood sash, u-value 72 1,714 0 2,414 2,414 <br /> 0.28, SHGC 0.32 <br /> 11N: Door-Metal- Polystyrene Core 42.2 1,254 0 355 355 <br /> 12F-Osw:Wall-Frame, R-21 insulation in 2 x 6 stud 4154.1 22,951 0 3,593 3,593 <br /> cavity, no board insulation, siding finish, wood studs <br /> 1560-10sf-4:Wall-Basement, , R-10 board insulation to 296.5 1,361 0 0 0 <br /> floor, no interior finish,4'floor depth <br /> 15B0-10sf-8: Wall-Basement, , R-10 board insulation to 1024.5 4,742 0 108 108 <br /> floor, no interior finish, 8'floor depth <br /> 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 2595 4,411 0 2,492 2,492 <br /> Floor(also use for Knee Walls and Partition <br /> Ceilings),Vented Attic, No Radiant Barrier, Dark <br /> Asphalt Shingles or Dark Metal,Tar and Gravel or <br /> Membrane, R-50 insulation <br /> 21A-32: Floor-Basement, Concrete slab, any thickness, 2 1485 2,525 0 0 0 <br /> or more feet below grade, no insulation below floor, <br /> any floor cover, shortest side of floor slab is 32'wide • <br /> 21A-28: Floor-Basement, Concrete slab, any thickness, 2 485 907 0 0 0 <br /> or more feet below grade, no insulation below floor, <br /> any floor cover, shortest side of floor slab is 28'wide <br /> 20P-30: Floor-Over open crawl space or garage, Passive, 649 1,930 0 182 182 <br /> R-30 blanket insulation, any cover <br /> Subtotals for structure: 56,485 0 26,781 26,781 <br /> People: 7 1,400 1,610 3,010 <br /> Equipment: 901 6,059 6,960 <br /> Lighting: o 0 0 <br /> Ductwork: 0 0 0 0 <br /> Infiltration: Winter CFM: 96, Summer CFM: 52 8,683 800 715 1,515 <br /> Ventilation: Winter CFM: 202, Summer CFM: 202 7,330 3,133 1,121 4,254 <br /> Exhaust: Winter CFM:202, Summer CFM:202 <br /> Humidification (Winter) 13.67 gal/day: 5,013 0 0 0 <br /> AED Excursion: 0 0 3,052 _ 3,052 <br /> Total Building Load Totals: 77,511 6,234 39,338 45,572 <br /> Qheck Figures <br /> Total Building Supply CFM: 1,790 CFM Per Square ft.: 0.322 <br /> Square ft. of Room Area: 5,565 <br /> Volume(ft3)of Cond. Space: 55,310 <br /> Building Loads <br /> Total Heating Required Including Ventilation Air: 77,511 Btuh 77.511 MBH <br /> Total Sensible Gain: 39,338 Btuh 86 % <br /> Total Latent Gain: 6,234 Btuh 14 % <br /> Total Cooling Required Including Ventilation Air: 45,572 Btuh <br /> iotas ', • • '. -:;•''.:7 . <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> • <br /> C:\...\TJB-393 Mallak.rh9 Wednesday, September 21,2016, 9:58 AM <br />