My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2005-P09113 - new septic system
Orono
>
Property Files
>
Street Address
>
O
>
Orchard Park Road
>
525 Orchard Park Road - 31-118-23-14-0002
>
Septic
>
2005-P09113 - new septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:29:24 PM
Creation date
4/27/2018 1:51:25 PM
Metadata
Fields
Template:
x Address Old
House Number
525
Street Name
Orchard Park
Street Type
Road
Address
525 Orchard Park Road
Document Type
Septic
PIN
3111823140002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
( ,'i ( copes-1 <br /> Rusty Olson's--Soil and Percolation Testing <br /> Joseph.J. Olson—MICA License#810 <br /> 11481 Riverview Rd.NE,Hanover,MN 55341 <br /> (763)498-8779 Fax(763)498-8290 <br /> August 17,2003 U 2-4 lb- 62 Z(o <br /> Randy Westrand o S <br /> 525 Orchard Park oad LO J l <br /> COrono,Henn.Co. / <br /> This on-site SewageTreatmentSystem is designed for a Type 1,three bedroom home in accordance with the <br /> Minnesota Pollution Control Agency Chapter 7080 and local ordinances. <br /> The seasonally saturated soils were located at 20"-32"(mottled soil). Due to seasonally saturated soils,a <br /> pressurized Mound System will need to be installed to treat septic effluent. The bottom of the treatment area must be <br /> located at least 3'above the saturated soils. <br /> The soils at a depth of 12"have a percolation rate averaging 7 MPI. <br /> All neighboring wells are located greater than 100' away from proposed treatment area. <br /> A variance will be needed to be closer than 75 feet from the wetland fringe. <br /> The existing tanks may be used upon approval of local inspector. <br /> The existing system does not conform to chapter 7080. <br /> A pumping chamber will need to be installed to lift the effluent to the treatment area. The power supply and <br /> switches must be located outside the manhole and pumping chamber in a weatherproof enclosure. A warning device <br /> must be installed with light and sound devices;this is in case of a pump failure. <br /> The manifold and supply line must have back drainage to the pumping chamber. The distribution pipes shall have <br /> their ends capped. Be sure the rock and sand fill materials are clean. The sod layer below the entire mounded area <br /> must be turned over,just break up the sod and be sure not to over work. <br /> Keep all heavy equipment off of the proposed treatment area before during and after construction. This <br /> Design is not valid and the System will need to be relocated if failure to protect the area proposed for On-Site <br /> Sewage Treatment occurs. <br /> With proper installation and maintenance,this system should have no problem in treating septic effluent effectively. <br /> Nothing other than gray water,(laundry,showers,etc.) Human water and toilet tissue should be disposed of into the <br /> septic tanks. Garbage disposals are not recommended. Additives must not be used;they may cause harmful damage <br /> to your septic system. It is recommended that you pump the tank every year for 1 tank every two years for two tanks. <br /> S..cerely, Miff" <br /> Oltelie <br /> �r .: t <br /> • 4 411'AII r' 420' <br /> Joseph J.Olson ' x • q4i <br /> i.74. rosters*mitineratit" <br /> APPIOVED WITS~TIMIS HI 1011110 <br /> as MDT AfTSOtl R IUMNAIMIT <br /> LSI +� ossirmwrawOwywtimibravika AI wit IAA*** <br /> 6 Nil wompilmwe oak wA apptiodb wail mhos fob.MNQOM$. lMIV*MAW IN tment Ilimakenestsadadieg IkonMill swifts*wad Is*hwk" <br /> INUMMES NIS OESIGN. UAW TWA PIM WOK NTS AsALL TOM <br />
The URL can be used to link to this page
Your browser does not support the video tag.