Laserfiche WebLink
.0, 0:4 <br /> 0 0 <br /> , „___ <br /> CITY of ORONO <br /> vi 41, rb <br /> 1$1, 'V ; ti <br /> Municipal Offices <br /> + t , :% , G <br /> X " ' O Street Address: <br /> Mailing <br /> 44 Y 750 Kelley Parkway P.O. Boxx 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323.0066 <br /> Owner: / ,',i0 b L'i--> �J/ Address:500 Orchard Park Rd. <br /> Permit #'s:5733 Dates:9/24/79 Contractors:Hayes Exc. <br /> (This is ( an existing system [ ] new construction) <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to <br /> design, construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, <br /> but in most respects appears to be designed, located, and constructed in accordance <br /> with previous codes and is functioning properly. <br /> 3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the <br /> current input; and any system with less than three feet of vertical se ion <br /> between the bottom 6f—tire-dre41 € e a sa urated- s�5t1�€ve . <br /> (The saturated soil level ,04, has or [ ] has not been identified at this time. If the <br /> saturated soil level has not been identified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 6 <br /> Pumpout not needed at this time <br /> /6% Solids accumulation in tanks indicates they should be pumped out this year. <br /> jj System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been <br /> pumped out within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If <br /> tanks have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanks [ ] were or 00 were not <br /> confirmed to be watertight by the licensed pumping contractor. If the tanks were not <br /> confirmed to be watertight, this classification is subject to revision.) <br /> INFIELD CONDITION (11-14) : 11 <br /> 1] Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medium <br /> COMMENTS: The non-compliant septic system must be repaired by 12/31/2006 or within 90 days <br /> of failure (surface�di(scharge) , whichever comes first. / <br /> oZ `/Ca /I, ��irL i1 _y/,.-- ---' <br /> Date of Inspection Seg is Sys em Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue <br /> to function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />