My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-01533 - septic
Orono
>
Property Files
>
Street Address
>
O
>
Orchard Park Road
>
460 Orchard Park Road - 32-118-23-23-0012
>
Septic
>
2016-01533 - septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:39:47 PM
Creation date
4/25/2018 11:06:47 AM
Metadata
Fields
Template:
x Address Old
House Number
460
Street Name
Orchard Park
Street Type
Road
Address
460 Orchard Park Road
Document Type
Septic
PIN
3211823230012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> INSPECTOR CHECKLIST - mound <br /> Lot L, block 1 Orchard harms <br /> ElWELL setbacks: 20'to pressure tested sewer line (5 psi for 15 min) <br /> 50'to everything 100'to dispersal area with shallow well <br /> PROPERTY LINES setback: 10'to everything <br /> Road setback: platted: 10'prop line. Metes&bounds: out of road easement, or outer ditch. <br /> LAKE/BLUFF setback: 20'for bluff. Lakes: GD_, RD_, NE . Protected Protected wetland_. <br /> Building setbacks: 10'for everything, 20'for dispersal area. <br /> WATER LINE under pressure se 10'to bed,tank E sewer line. (else sewer line> 12"below) <br /> 0 Sewer line&baffle connection (no 90's, 3'between 45's, slope min 1"in 8', max 2"in 8') <br /> (no depth req's, clean out every 100', Sch 40 pipe) <br /> • Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br /> mfe 2250 gallons none <br /> Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br /> No effluent filter&alarm <br /> Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br /> mfe 1300 gallons <br /> • dose pump 36 gpm 26 head VERIFY PUMP CURVE 6.3 min ON 9 hr OFF <br /> 0 float setting drop 8.9 inches at 25.5 gpi "DESIGNED" 5.5 inches approx float tether length <br /> 227.0 gal dose divided by gpi "INSTALLED"= inches float drop(field corrected <br /> LABEL pump requirements and drawdown on riser or panel <br /> Cam lock reachable from grade - 30"max. J-hook weep hole. Supply line access (no hard 90's) <br /> 2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4"sch40 sleeve or compacted, and buried 6"+. <br /> _ splice box/ control panel / electrical connections <br /> _ flow measurement: CT, ETM, time dosed, home water meter <br /> _ mound absorption area rough up <br /> _ mound rock dimensions 10.0 X 63.0 <br /> Sand lift depth 20 inches. (Jar test: 2"sand leaves 1/8"silt after 30 min) <br /> O Absorption Sand beyond rock 0.0 upslope 17.0 downslope <br /> Bermed topsoil beyond rockbed 11 upslope 13 sideslope 26 downslope <br /> cover depth of 12-18"+ VERIFY <br /> _ 3 laterals (1-2'from edge of rock) <br /> 2.00 inch pipe size (Sch40 pipe&fittings) <br /> 3.0 ft lateral spacing <br /> 7/32 inch perforations <br /> 3.0 ft perforation spacing <br /> Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br /> clean outs (no hard 90's) <br /> 4"inspection pipe to bottom of rock, anchored VERIFY <br /> Abandon existing system - if necessary Re-use existing tank certification <br /> _ monitoring plan and type <br /> well abandonment form - if necessary <br />
The URL can be used to link to this page
Your browser does not support the video tag.