My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
O
>
Orchard Park Road
>
460 Orchard Park Road - 32-118-23-23-0012
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:39:49 PM
Creation date
4/25/2018 10:27:52 AM
Metadata
Fields
Template:
x Address Old
House Number
460
Street Name
Orchard Park
Street Type
Road
Address
460 Orchard Park Road
Document Type
Septic
PIN
3211823230012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
eils • <br /> RECEIVED <br /> Kochi's Soil Testing <br /> Box 81 MAY 2 6 2015 <br /> Loretto, Minn. 55357 <br /> Tel 763-479-2637 <br /> CITY OF ORONO <br /> Compliance Inspection of an existing Mound System <br /> Bob Rohden <br /> • <br /> 460-Orchad Park Dr., 5/25/2015 <br /> Orono, Minn. <br /> Job Site;Above Address. <br /> Type of drainfield installed—Mound System (Installed---6/19/1992 <br /> Size of Mound; --80 ft. long by 35 ft. wide(Ave, Size) <br /> Rock Bed Size--; 55 ft.long by 10 ft. wide (550 sq. ft. ) <br /> (Sized out for a 4 bedroom home or ¢00 gal/day daily water use) <br /> * Mound System consist of; Topsoil& Sandy Loam-12 inches, Rock–12 inches 12 inches of Sand <br /> (Total mound height-36 inches---3.0 ft.. ) <br /> . Size of Septic Tanks; ---2-1000 gallon sealed tanks <br /> Size of pump tank ---- 1-1000 gallon sealed tank <br /> Upon inspection of the mound system there was not any signs of effluent from the mound system onto to <br /> the surface or into any field tile. <br /> Upon inspection of the house there was not any signs of sewage backing up into the house. <br /> The tanks (septic and pump tank)were probed and the appear to be sealed tanks at this time <br /> Date: 5/15/2015 <br /> The pump was tested out an it appears to be in good working order,also the alarm system was tested and <br /> was working as of this dated 5/15/2015. <br /> Two soil borings were done to determine where the mottled soil level was at; <br /> Soil boring#1 was done in the North West upslope of the mound. <br /> Soil Boring was done approximately 20 ft. West of the mound Northwest upslope toe <br /> (Sand depth is approximately 12 inches (1.0 ft.) below the rock bed.). <br /> Mottled soil was at the following depths; <br /> SB# 1 48 inches (2. 0 ft. below the mound sand depth) <br /> SB #2 29 inches <br /> level) <br /> Mottled soil is consider the high seasonalsaturate soil level hat existoriginal <br /> at duringthetopsoil <br /> seasons. <br /> With the sand depth of- 12 inches ( 1,0 ft.) below the rock bed area in the mound system and <br /> The mottled soil at depths of-48 inches(4.0 ft.)and at 29 inches(2.4 ft.) <br /> The t required 2-foot (24 inches)separation distance from the bottom of the rock bed to mottled soil level <br /> is satisfied. <br /> With the above information this mound system is consider to be A COMPLIANT SYSTEM <br /> According to the current Minn.. Rules 7080 AND CURRENT LOCAL CODES, <br /> Sit Evaluator �q <br /> Robert A, Koch M.P.C.A. # 193/1429 <br /> I <br />
The URL can be used to link to this page