Laserfiche WebLink
New Construction Energy Code Compliance Certificate <br /> Date Certificate Post <br /> Per R401.3 Certificate.A building certificate shall be posted on or in the electrical distribution panel. <br /> Place your <br /> Mailing Address of the Dwelling or Dwelling Unit City logo here <br /> 1180 Hunter Drive Orono <br /> Name of Residential Contractor MN License Number <br /> Wooddale Builders BC002926 <br /> THERMAL ENVELOPE RADON CONTROL SYSTEM <br /> Type:Check All That Apply X Passive(No Fan) <br /> /ALARM twirl jail arlu rnuriUmeler <br /> r o CD or other system monitoring <br /> h yr A.,„,,r„ <br /> CUP ,oR6No <br /> 0 <br /> F0N Location(or future location)of Fan: <br /> T <br /> s — -O O <br /> as U C N d O <br /> 0 a <br /> N O- O 0 'D (_) <br /> N <br /> CO Q m m a O = T <br /> O <br /> ui O <br /> z 2 2 v 1 w 0 <br /> Insulation Location ty ° ` mm 0 w N <br /> mmo E E ao a <br /> i 'mo vo -o a o o 2 a> <br /> ✓ c z it i tL w <br /> CL it Other Please Describe Here <br /> Below Entire Slab X <br /> Foundation Wall R-15 X R10 ext.&r5 Int. <br /> Perimeter of Slab on Grade X <br /> Rim Joist(1st Floor) R-20 X Spray Foam <br /> Rim Joist(2nd Floor+) R-20 X Spray Foam <br /> Wall R-21 X <br /> Ceiling,flat R-49 X <br /> Ceiling,vaulted R-49 X <br /> Bay Windows or cantilevered areas R-38 X <br /> Floors over unconditioned area R-38 X R-38 Below ducts <br /> Describe other insulated areas <br /> Building envelope air tightness: Duct system air tightness: <br /> Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces <br /> Average U-Factor(excludes skylights and one door)U: 0.31 x Not applicable,all ducts located in conditioned space <br /> Solar Heat Gain Coefficient(SHGC): 0.29 R-value <br /> MECHANICAL SYSTEMS Make-up Air Select a Type <br /> Appliances Heating System Domestic Water Cooling System <br /> Heater x Not required per mech.code <br /> Fuel Type Natural Gas Electric Electric Passive <br /> Manufacturer Rheem Westinghouse Rheem Powered <br /> R96VA0851521 MSA RA1348AJ1 NA Interlocked with exhaust device. <br /> Model R96VA0602317MSA WEC100C2X045 RA1324AJ1NA Describe: <br /> Input in 84000 Capacity in 100 Output 4 and 2 Other,describe: <br /> BTUS: 56000 Gallons: in Tons: <br /> Rating or Size <br /> AFUE or 96%,96% 98% SEER 13 and 13 Location of duct or system: <br /> Efficiency HSPF% /EER <br /> Heating Loss Heating Gain Cooling Load <br /> Residential Load Calculatik 120844 65846 71100 <br /> Cfm's <br /> "round duct OR <br /> MECHANICAL VENTILATION SYSTEM "metal duct <br /> Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type <br /> source heat pump with gas back-up furnace): x Not required per mech.code <br /> Select Type Passive <br /> Heat Recover Ventilator(HRV) Capacity in cfms: Low: 128 High: 255 Other,describe: <br /> Energy Recover Ventilator(ERV)Capacity in cfms: Low: High: Location of duct or system: <br /> Balanced Ventilation capacity in cfms: <br /> Location of fan(s),describe: Cfm's <br /> Capacity continuous ventilation rate in cfms: 60 and 75 "round duct OR <br /> Total ventilation(intermittent+continuous)rate in cfms: 120 and 150 "metal duct <br /> Builders Associaton of Minnesota version 101014 <br />