Laserfiche WebLink
2011 purple code Mound Design <br /> www.SepticResource.com (vers 15.2) <br /> Property Owner: Wooddale Builders Date: 12/6/2017 <br /> Site Address: 1180 Hunter Drive PID: 2511823420006 <br /> Comments: <br /> instructions: = enter data = adjust if desired = computer calculated - DO NOT CHANGE! <br /> I) 5 bedroom Type I Residential System <br /> 750 GPO design flow <br /> ;, Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks <br /> 4) 2250 Gal Septic tank (code minimum) 2250 Gal Septic tank (design size / LUG req'd) <br /> Tank options: none <br /> ;, 1.2 GPD/ft2 mound sand loading rate contour loading rate of 12 req's a min 62.5 ft. long rockbed <br /> 6) 10.0 ft rockbed width 63.0 ft rockbed length <br /> 7) 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br /> end feed manifold connection <br /> s, 3 laterals 61.0 feet long 21.0 perfs / lateral 63 perfs total <br /> (1/2 a perf means the first perf starts at the middle feed manifold) <br /> 7/32 inch perfs at 1 feet residual head gives 0.56 gpm flow rate per perforation <br /> for this perf size &t spacing, a pipe size on line 12, max perfs/lateral = 30 , line #8 must be less --> OK <br /> iu) 4.0 doses per day ( 4 minimum) <br /> I i; 188 gallons per dose (treatment volume) <br /> 2.00 5x <br /> 12) 2.00 inch diameter laterals must be used to meet"4x pipe volume" requirement <br /> 2.00 3x <br /> 13) 238 feet of 2.0 inch supply line leads to 40 gallons of drainback volume <br /> (Tip: "top feed" manifold to control the drainback) <br /> 14) 228 gallons TOTAL pump out volume (treatment+ drainback) <br /> 15) 11 feet vertical lift from pump to mound laterals, leads to a: <br /> 16) 36 GPM @ 26 feet of head, Pump requirement (note: >50gpm may require an extra 3-6'of head) <br /> 17, 750 gal Dose tank (code minimum) 1300 gal Dose tank (design size / LUG req'd) at 25.49 gpi <br /> leads to a <br /> is) 8.9 inch swing on Demand float, or timed dosing of 6.3 min ON (confirm pump rate with drawdown <br /> (this delivers Average flow, =70%of Peak design flow) 9 hrs OFF test and adjust as necessary) <br /> 10) 12 inches from bottom of tank to "Pump OFF"float <br /> 20, 21 inches from bottom of tank to "Pump ON" float, or 12 inches to "Timer ON"float if time dosed <br /> 21) 24 inches from bottom of tank to "Hi Level" float, or 34 inches to "Hi Level" float if time dosed <br /> 22) 688 gallons reserve capacity (after High Level Alarm is activated) <br />