My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-00692 - new structure
Orono
>
Property Files
>
Street Address
>
O
>
Oliver Hill
>
2345 Oliver Hill - 34-118-23-33-0076
>
Permits/Inspections
>
2017-00692 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:57:24 PM
Creation date
4/23/2018 12:57:52 PM
Metadata
Fields
Template:
x Address Old
House Number
2345
Street Name
Oliver
Street Type
Hill
Address
2345 Oliver Hill
Document Type
Permits/Inspections
PIN
3411823330076
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Directions-The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening,is called the Known Air <br /> Infiltration Rate Method.For new construction,4b of step 4 is required to be filled out. <br /> IFGC Appendix E,Worksheet E-1 <br /> Residential Combustion Air Calculation Method <br /> (for Furnace,Boiler,and/or Water Heater in the Same Space) <br /> Step 1:Complete vented combustion appliance information. <br /> Furnace/Boiler: 80000 <br /> Draft Hood Dan Assisted Direct Vent Input: Btu/hr or Power Vent <br /> Water Heater: <br /> Draft Hood IIFan Assisted Direct Vent Input: Btu/hr or Power Vent <br /> Step 2:Calculate the volume of the Combustion Appliance Space(CAS)containing combustion appliances. <br /> The CAS includes all spaces connected to one another by code compliant openings. CAS volume: 0 ft3 <br /> LxWxH ow EH <br /> Step 3:Determine Air Changes per Hour(ACH)1 <br /> Default ACH values have been incorporated into Table E-1 for use with Method 4b(KAIR Method).If the year of construction or ACH is not known,use <br /> method 4a(Standard Method). <br /> Step 4:Determine Required Volume for Combustion Air.(DO NOT COUNT DIRECT VENT APPLIANCES) <br /> 4a.Standard Method <br /> Total Btu/hr input of all combustion appliances Input: Btu/hr <br /> Use Standard Method column in Table E-1 to find Total Required TRV: ft3 <br /> Volume(TRV) <br /> If CAS Volume(from Step 2)is greater than TRV then no outdoor openings are needed. <br /> If CAS Volume(from Step 2)i s less th an TRV then go to STEP S. <br /> 4b.Known Air Infiltration Rate(KAIR)Method(DO NOT COUNT DIRECT VENT APPLIANCES) <br /> Total Btu/hr input of all fan-assisted and power vent appliances Input: 0 Btu/hr <br /> Use Fan-Assisted Appliances column in Table E-1 to find RVFA: ft3 <br /> Required Volume Fan Assisted(RVFA) <br /> Total Btu/hr input of all Natural draft appliances Input: Btu/hr <br /> Use Natural draft Appliances column in Table E-1 to find RVNFA: ft3 <br /> Required Volume Natural draft appliances(RVNDA) <br /> Total Required Volume(TRV)=RVFA+RVNDA TRV= 0 + 0 = O TRV ft3 <br /> Step 5:Calculate the ratio of available interior volume to the total required volume. <br /> Ratio=CAS Volume(from Step 2)divided by TRV(from Step 4a or Step 4b) <br /> Ratio= 0 / 0 = NaN <br /> Step 6:Calculate Reduction Factor(RF). <br /> RF=lminus Ratio RF=1- 0.00 = 1 .00 <br /> Step 7:Calculate single outdoor opening as if all combustion air is from outside. <br /> Total Btu/hr input of all Combustion Appliances in the same CAS Input: 0 Btu/hr <br /> (EXCEPT DIRECT VENT) <br /> Combustion Air Opening Area(CAOA): <br /> Total Btu/hr d I vid ed by 3000 Btu/hr per in: CAOA= 0 /3000 Btu/hr per inz= 0.00 in: <br /> Step 8:Calculate Minimum CAOA. <br /> Minimum CAOA=CAOA multiplied by RF Minimum CAOA= 0.00 x 1 .00 = 0.00 in: <br /> Step 9:Calculate Combustion Air Opening Diameter(CAOD) <br /> CAOD=1.13 multiplied by the square root of Minimum CAOA CAOD=1.13 V Minimum CAOA= in.diameter go up one inch in size <br /> if using flex duct <br /> 1 If desired,ACH can be determined using ASHRAE calculation or blower door test.Follow procedures in Section <br /> G304. <br />