New Construction Energy Code Compliance Certificate <br /> Per NI 101.8 Building Certificate.A building certificate shall be posted in a permanently visible location inside Date Certificate Posted <br /> the building. The certificate shall be completed by the builder and shall list information and values of <br /> components listed in Table N1101.8. 4/5/17 <br /> Mailing Address of the Dwelling or Dwelling Unit City DOVER II <br /> 2335 Oliver Hill Orono <br /> Name of Residential Contractor MN License Number <br /> Youngfield Homes BC627670 <br /> THERMAL ENVELOPE RADON SYSTEM <br /> Type:Check All That Apply X Passive(No Fan) <br /> o i 0 <br /> y n = <br /> H <br /> 4 Active(With fan and monometer or <br /> a, <br /> a other system monitoring device) <br /> o <br /> '0 0 <br /> P. <br /> L <br /> ! 4 * iIi <br /> Insulation Location , Z 2 A u g' _, w o <br /> " .= 0 t t § p u .v_" b <br /> F0- C Z w w u. w0 2 r�G w Other Please Describe Here <br /> Below Entire Slab X <br /> Foundation Wall R-15 X 2"&3"POLYURETHANE <br /> Perimeter of Slab on Grade X <br /> Rim Joist(Foundation) R-20 X BASF 178 <br /> Rim Joist(l81 Floor+) R-20 X BASF 178 I <br /> Wall R-21 X GUARDIAN FIBERGLASS <br /> Ceiling,flat R-49 X GUARDIAN FIBERGLASS <br /> Ceiling,vaulted R-49 X GUARDIAN FIBERGLASS <br /> Bay Windows or cantilevered areas X <br /> Bonus room over garage R-30 X BASF 178 <br /> Describe other insulated areas All windows&doors-non expanding window foam- HILTI FOAM <br /> Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces . <br /> Average U-Factor(excludes skylights and one door)U: 0.29 Not applicable,all ducts located in conditioned space <br /> Solar Heat Gain Coefficient(SHGC): 0.28 X R-8 AT ATTIC AND GARAGE <br /> MECHANICAL SYSTEMS 1 Make-up Air Select a Type <br /> Appliances Heating System Domestic Water Heater Cooling System X Not required per mech.code <br /> Fuel Type Natural _ELECTRIC R-410A Passive <br /> Manufacturer Bryant RHEEM Bryant Powered <br /> Interlocked with exhaust device. <br /> Model 912SB48080S17 MARATHON BA13NA042 Describe: <br /> Input in 80,000 Capacity in 50 Output in 3.5 Other,describe: <br /> Rating or Size BTUS: Gallons: Tons: <br /> Heat Loss: 61,232 Heat 31,324 Location of duct or system: <br /> Structure's Calculated Gain: <br /> AFUE or 92% SEER: 13 <br /> HSPF% <br /> Calculated 37,886 <br /> Efficiency cooling load: Cfm's <br /> "round duct OR <br /> Mechanical Ventilation System i "metal duct <br /> Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type <br /> source heat pump with gas back-up furnace): X Not required per mech.code <br /> Select Type Passive , <br /> Heat Recover Ventilator(HRV) Capacity in cfms: Low: High: Other,describe: <br /> X Energy Recover Ventilator(ERV)Capacity in cfms: Low: 40%=124 High: 70%=217 Location of duct or system: ' <br /> Continuous exhausting fan(s)rated capacity in cfms: furnace room <br /> Location of fan(s),describe: I Cfm's <br /> Capacity continuous ventilation rate in cfms: _95 "round duct OR FLEX <br /> Total ventilation(intermittent+continuous)rate in cfms: 190 "metal duct <br /> Created by BAM version 052009 <br />