Laserfiche WebLink
hvac '; s 4 4°d '(4 T� :14,7 HVA ads A �„ S } v X"`AM <br /> ,1 +-.. f a r u't z , t.).-161,,;_.,,,,,,.,7,-:,,-. � +F Sl <br /> - ,1"y`.. ib .1,:;.,,r :4- <br /> ','N‘,. •.• 'a ; a "N 5t„ 5. t1. ,'z 3L"°r ` Y :)A ' rg g y' <br /> z �. ,,a°��,ra. v FL �t�erx ..�v,,.��' �-��.�.u,..•, .3�. _., .�rti t��i',.,: � . . ' �:r 3 t�,r fir."4 c..�• ,fl. <br /> x <br /> Total Building Summary Loads <br /> LOW EE: Glazing-Builder Grade Low E Windows& 432.8 12,046 0 6,116 6,116 <br /> Sliding Door.32 U value.30 SHGC, u-value 0.32, <br /> SHGC 0.3 <br /> 11J: Door-Metal- Fiberglass Core 37.8 1,972 0 544 544 <br /> 15A-10sffc-8: Wall-Basement, concrete block wall, R-10 992 3,624 0 0 0 <br /> foam board to floor, no framing, no interior finish, <br /> filled core, 8'floor depth <br /> R-20 12F-Osw: Wall-Frame, Custom, no board insulation, 2569.5 14,755 0 2,255 2,255 <br /> siding finish,wood studs <br /> RJ R20 Closed Cell: Wall-Frame, Custom, Spray Foam R- 504 2,192 0 388 388 <br /> 20 <br /> R49- 16B-49: Roof/Ceiling-Under Attic with Insulation on 1760 3,522 0 1,943 1,943 <br /> Attic Floor(also use for Knee Walls and Partition <br /> Ceilings), Custom, R49 Blown Insulation-vented <br /> attic, asphalt shingles <br /> 21A-20-c: Floor-Basement, Concrete slab, any thickness, 1443 3,390 0 0 0 <br /> 2 or more feet below grade, no insulation below floor, <br /> carpet covering, shortest side of floor slab is 20'wide <br /> 20P-30: Floor-Over open crawl space or garage, Passive, 318 968 0 89 89 <br /> R-30 blanket insulation, any cover <br /> Subtotals for structure: 42,469 0 11,335 11,335 <br /> People: 5 1,000 1,150 2,150 <br /> Equipment: 901 4,116 5,017 <br /> Lighting: 1250 4,263 4,263 <br /> Ductwork: 2,837 231 581 812 <br /> Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 <br /> Ventilation: Winter CFM: 190, Summer CFM: 190 7,057 4,409 1,054 5,463 <br /> Humidification (Winter) 17.34 gal/d _ 6 359 0 _._ 0 0__ <br /> Total Building Load Totals: 58,723 6,541 22,499 29,039 <br /> f v {. 4; .kAV .,.r,a7, Gywjs.,:wsx„ .z ... `` 7` A, w " > , .. . ° !t. ,.. .. ".rt'b,Yz. <br /> Total Building Supply CFM: 1,001 CFM Per Square ft.: 0.215 <br /> Square ft. of Room Area: 4,646 Square ft. Per Ton: 1,920 <br /> Volume (ft3)of Cond. Space: 37,168 <br /> •:,,.., ,ti � tg {2.4.1:1%;.1A -..:.;%,:17,,,-a <br /> : ;:: i° ,:.:7" ti ., h , '....';',.'„%.'2c v :`" 4 t" wr, r.,.,. . 4 ti�a ',i <br /> Total Heating Required Including Ventilation Air: 58,723 Btuh 58.723 MBH <br /> Total Sensible Gain: 22,499 Btuh 77 % <br /> Total Latent Gain: 6,541 Btuh 23 % <br /> Total Cooling Required Including Ventilation Air: 29,039 Btuh 2.42 Tons(Based On Sensible+ Latent) <br /> A; 9 y y,y 4 k .g,r s. 4' <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> M:\Sales and Estimating\Heat Calcs\Country Joe Homes\2330 Oliver Hill Orono.rh9 Tuesday, January 16, 2018, 2:21 PM <br />