Laserfiche WebLink
• <br /> New Construction Energy Code Compliance Certificate /// <br /> Per N1101.8 Building Certificate.A building certificate shall be posted in a permanently visible location inside the Date Certificate Posted <br /> building. The certificate shall be completed by the builder and shall list information and values of components <br /> listed in Table N1101.8. 10/24/14 0 r 0 n <br /> Mailing Address of the Dwelling or Dwelling Unit City a r e s <br /> TBD-Almsted Custom Home Orono CONSTRUCTION <br /> Name of Resldentlal Contractor MN License Number <br /> GORDON JAMES CONSTRUCTION BC531961 <br /> THERMAL ENVELOPE RADON SYSTEM <br /> Type:Check All That Apply X Passive(No Fan) <br /> w <br /> o d <br /> N C. <br /> F -. Active(With fan and monometer or <br /> >, other system monitoring device) <br /> °' o 7, U .off b i <br /> Io • Pa { N V <br /> O <br /> . i h O d W o <br /> Insulation Location 4 '' c V O ' <br /> o y o a s o 0 la 1a4 <br /> F ,.q Z w w w w a is Other Please Describe Here <br /> Below Entire Slab --- X <br /> Foundation Wall w/Waterproofing R-5 X Exterior wiwaterproofing <br /> Perimeter of Slab on Grade(2"Rigid on Fnd wall) X <br /> Rim Joist(Foundation) 2 1/4"Thick X Type in location:interior exterior or integral <br /> Rim Joist(1u Floor+) 2 1/4"Thick X Type In location:Interior exterior or integral <br /> wall R-19 X 111 <br /> Ceiling,flat(attic) R-44 X <br /> Ceiling,vaulted(attic) R-44 X <br /> Bay Windows or cantilevered areas R-34 X <br /> Bonus room over garage R-38 <br /> Describe other Insulated areas <br /> Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces <br /> Average U-Factor(excludes skylights and one door)U: 030 Not applicable,all ducts located in conditioned space <br /> Solar Heat Gain Coefficient(SHGC): 032 21 R-value <br /> F <br /> MECHANICAL SYSTEMS I __ , __ Make-up Air Select a Type <br /> Appliances Heating System Domestic Water Heater Cooling System Not required per mech.code <br /> Fuel Type Gas Gas Electric X Passive <br /> Manufacturer Carrier Rheem Carrier Powered <br /> Interlocked with exhaust device. ' <br /> Model 59SC5100 42VP75FW 24ABB348 Describe: <br /> Input in 100 000 Capacity in 75 Output in 4 TONS Other,describe: <br /> Rating or Size BTUS: Gallons: Tons: <br /> Heat Loss: Heat Gain: 41612 Location of duct or system: <br /> Structure's Calculated 89,112 <br /> AFUEor SEER: 13 MECHANICAL ROOM <br /> HSPF% 95.6% <br /> .Calculated 46,215 <br /> Efficiency cooling load: Cfin's <br /> • I 6 "round duct OR <br /> Mechanical Ventilation System "metal duct <br /> Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type <br /> source heat pump with gas back-up furnace): NONE _ Not required per mech.code <br /> Select Type X Passive <br /> X Heat Recover Ventilator(HRV) Capacity in cfins: Low: High: Other,describe: <br /> Energy Recover Ventilator(ERV)Capacity in cflns: Low: High: 200 Location of duct or system: <br /> Continuous exhausting fan(s)rated capacity in cfins: MECHANICAL ROOM <br /> Location of fan(s),describe: !BATHROOMS 70 Cfin's <br /> Capacity continuous ventilation rate in cfins: 6 "round duct OR <br /> Total ventilation(intermittent+continuous)rate in cfins: 200 "metal duct <br /> ' O...,.l..J l.,D/.h1..,...:.,..0Ct0136- <br />