My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-00375 - new structure
Orono
>
Property Files
>
Street Address
>
G
>
Goldenrod Way
>
2837 Goldenrod Way - 33-118-23-24-0028
>
Permits/Inspections
>
2018-00375 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:47 PM
Creation date
4/18/2018 8:10:39 AM
Metadata
Fields
Template:
x Address Old
House Number
2837
Street Name
Goldenrod
Street Type
Way
Address
2837 Goldenrod Way
Document Type
Permits/Inspections
PIN
3311823240028
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br /> New Construction Energy Code Compliance Certificate <br /> Date Certificate Posted MAR 8 ^ <br /> Per R401.3 Building Certificate.A building certificate shall be posted on or in the electrical distribution panel. 8/31/17 2 2018 <br /> Mailing Address of the Dwelling or Dwelling Unit <br /> 7822-A GIV Q1=ORONO <br /> Name of Residential Contractor MN License Number <br /> David Weekley Homes <br /> City Plan ID <br /> 7822 <br /> THERMAL ENVELOPE IRADON CONTROL SYSTEM <br /> Type:Check All That Apply X Passive(No Fan) <br /> w <br /> o v <br /> FActi'iORL <br /> ve(With fan and monometer or <br /> _, c <br /> O other system monitoring device) <br /> 65. a tutoir ...g ... <br /> Ir o <br /> 7 ¢ -) U 2 "E g Location(or future Location)of Fan: <br /> Insulation Location a .F z, U w <br /> 4 § 5 s -a <br /> H z Jr. w w v2 n a a Other Please Describe Here <br /> Below Entire Slab X <br /> Foundation Wall R-10 X exterior <br /> Perimeter of Slab on Grade X <br /> Rim Joist(1st Floor) R-20 X Interior <br /> Rim Joist(2nd Floor) R-20 X Interior <br /> Wall R-20 X <br /> Ceiling,flat R-49 X <br /> Ceiling,vaulted R-30 X <br /> Bay Windows or cantilevered areas R-30 X <br /> Floors over unconditioned areas R-38 X <br /> Describe other insulated areas <br /> IBuilding Envelope air Tightness: Duct system air tightness: <br /> Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces <br /> Average U-Factor(excludes skylights and one door)U: .27-.31 Not applicable,all ducts located in conditioned space <br /> Solar Heat Gain Coefficient(SHGC): .25-.29 R-8 R-value <br /> MECHANICAL SYSTEMS I Make-up Air Select a Type <br /> Appliances Heating System Domestic Water Heater Cooling System X Not required per mech.code <br /> Fuel Type NAT GAS NAT GAS R-410A Passive <br /> Manufacturer Bryant Rheem Bryant Powered <br /> Interlocked with exhaust device. <br /> Model 912SB48060S21 PROG5042NRH67PV BA13NA030 Describe. <br /> Input in 60000 Capacity in 50 Output in 2.5 Other,describe: <br /> Rating or Size BTUS: Gallons: Tons: <br /> AFUE or 92% SEER or 13 Location of duct or system: <br /> Efficiency HSPF% EER <br /> HEAT LOSS HEAT GAIN COOLING LOAD <br /> RESIDENTIAL LOAD CALL 43949 22724 27790 <br /> Cfm's <br /> 1 "roan Ouct uR <br /> Mechanical Ventilation System "metal duct <br /> Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type <br /> source heat pump with gas back-up furnace Not required per mech.code <br /> Select Type X Passive <br /> Heat Recover Ventilator(HRV) Capacity in cfms: Low: High: Other,describe: <br /> Energy Recover Ventilator(ERV)Capacity in dins: Low: 50%=88 High: 90°4=158 Location of duct or system: <br /> Balanced Ventilation Capcity in CFMS: furnace room <br /> Locations of Fans,describe: Cfm's <br /> Capacity continuous ventilation rate in c1ms: 73 5 "round duct OR <br /> Total ventilation(intermittent+continuous)rate in cons: 145 "metal duct <br />
The URL can be used to link to this page
Your browser does not support the video tag.