Laserfiche WebLink
INSPECTOR CHECKLIST - mound <br /> 4LU Lakeview Parkway <br /> EijV'F.E.I. setbacks: 20'to pressure tested sewer line (5 psi for 15 min) <br /> 50'to everything 100'to dispersal area with shallow well <br /> PROPERTY LINES setback: 10'to everything <br /> Road setback: platted: 10'prop line. Metes Et bounds: out of road easement, or outer ditch. <br /> LAKE /BLUFF setback: 20'for bluff. Lakes: GD_, RD , NE Protected wetland_. <br /> Building setbacks: 10'for everything, 20'for dispersal area. <br /> WATER LINE under pressure sc 10'to bed,tank Et sewer line. (else sewer line> 12"below) <br /> ElSewer line Et baffle connection (no 90's, 3'between 45's, slope min 1"in 8', max 2"in 8') <br /> (no depth req's, clean out every 100', Sch 40 pipe) <br /> 0 Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br /> mfg 2250 gallons none <br /> Riser over outlet, riser over inlet or center, and 6"+inspection pipe over any remaining baffles. <br /> _ No effluent filter Et alarm <br /> Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br /> mfg 1300 gallons <br /> El dose pump 36 gpm 16 head VERIFY PUMP CURVE 5.3 min ON 9 hr OFF <br /> 0 float setting drop 7.5 inches at 25.5 gpi "DESIGNED" 4.8 inches approx float tether length <br /> 192.0 gal dose divided by gpi "INSTALLED"= inches float drop(field corrected <br /> LABEL pump requirements and drawdown on riser or panel <br /> Cam lock reachable from grade - 30"max. J-hook weep hole. Supply tine access (no hard 90's) <br /> 2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4"sch40 sleeve or compacted, and buried 6"+. <br /> _ splice box / control panel /electrical connections <br /> flow measurement: CT, ETM, time dosed, home water meter <br /> mound absorption area rough up <br /> _ mound rock dimensions 10.0 X 63.0 <br /> Sand lift depth 14 inches. (Jar test : 2"sand leaves< 1/8"silt after 30 min) <br /> nAbsorption Sand beyond rock 0.0 upslope 17.0 downslope <br /> Bermed topsoil beyond rockbed 9 upslope 13 sideslope 30 downslope <br /> cover depth of 12-18"+ VERIFY <br /> _ 3 laterals (1-2'from edge of rock) <br /> 2.00 inch pipe size (Sch40 pipe Et fittings) <br /> 3.0 ft lateral spacing <br /> 7/32 inch perforations <br /> 3.0 ft perforation spacing <br /> Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br /> clean outs (no hard 90's) <br /> 4"inspection pipe to bottom of rock, anchored VERIFY <br /> Abandon existing system - if necessary Re-use existing tank certification <br /> _ monitoring plan and type <br /> well abandonment form - if necessary <br />