Adequate Exposure Diversity <br /> AED Graph <br /> 15000 <br /> 10000 <br /> v <br /> 0 <br /> 5000 <br /> 0 <br /> 8am 9am 10am 11am 12pm 1pm 2pm 3pm 4pm 5pm 6pm 7pm 8pm <br /> r <br /> — Hourly Loads — Average <br /> Equipment selection <br /> System equipment selection will be made using the following derived values. <br /> Glass (W) 141 sq. ft. <br /> Glass (N) 20 sq. ft. <br /> Glass (S) 20 sq. ft. <br /> Glass (E) 99 sq. ft. <br /> Summer Outdoor 92°F <br /> Summer Wet Bulb °F <br /> Summer Indoor 70°F <br /> Summer Design Grains 50% <br /> Winter Outdoor -15°F <br /> Winter Indoor 70°F <br /> Sensible Cooling 23,907 Btuh <br /> Latent Cooling 3,232 Btuh <br /> Required Cooling Airflow 1,087 CFM <br /> Sensible Heating 69,010 Btuh <br /> Required Heating Airflow 896 CFM <br /> SOFTWARE VALIDATION:All calculations are based upon approved HVAC industry standards and procedures,ACCA Manual J 8th Edition <br /> calculations,retrieved weather data based on NOAA locations nearest the home being investigated.The code uses BIN data and not heating or <br /> cooling degree day methods.The house image is pulled from Google Earth and the real estate data is pulled from Zillow(when available). <br /> All calculations comply with all local,state and federal code requirements and meet or exceed the requirements of the 2012 International Energy <br /> Conservation Code(IECC)paragraph 403.6 in their entirety as verified by independent engineer William M.McMahon Jr.P.E.CEM.The <br /> programs are properly based on standard engineering heat loss/heat gain formulas coupled with the appropriate weather data,location factors, <br /> general home construction materials,user designated for energy unit costs,and other considerations normally used in the HVAC industry.It is <br /> my professional opinion,that the program,while consistent with calculations in ACCA Manual J,can be considered as meeting the"other <br /> approved heating and cooling calculation methodologies"and do not require approval from ACCA. <br /> Further,Paul Welch,P.E.;FL Reg.No.29945 affirmed that the software computes building heating and cooling loads and sizes equipment in a <br /> manner consistent with good engineering practice and approved heating and cooling load calculations methodologies and fully complies with <br /> Florida Building Code and Energy Conservation Codes.All computed results are estimates.Product developed and maintained by Energy Design <br /> Systems,Inc. <br />