Laserfiche WebLink
-4,--- <br /> N. <br /> CITY OF ORONO O <br /> Municipal Offices O O <br /> Post Office Box 66 A'' , <br /> Crystal Bay, MN 55323-0066 P ON—SITE SEWAGE TREATMENT <br /> �'i �ijl' �, INSPECTION REPORT <br /> kEsH.o�� <br /> Owner: lh2)41%C.N Address: 9•16-401d/.0 /eke. Rd, <br /> Permit #'s: ANC Dates: — Contractors: IA)k= +N\ <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is 4.an existing system I ] new construction) <br /> SYSTEM CONFORMITY (1-3): <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> 0 any pollutants into ground or surface waters. <br /> �3/ "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand <br /> -5)('-' <br /> between the distribution device and the limiting soil cnaracterrstTcs. s <br /> (The limiting soil characteristic has or I ] has not been identified' at1thistim(. )If the limiting <br /> characteristic has not been idents ied, this classification may be subject to revision.) soil <br /> TANK CONDITION (5-10): S <br /> Wj inspection indicates: <br /> '..5 Punpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. <br /> 7 Solids accumulation in tanks is at a critical level. Tanks should be pupped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each <br /> tank at next pumpout. If tanks have not been pupped out within the last three years, they should be pumped <br /> out now. <br /> 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). <br /> If tanks have not been pumped out within the last three years, they should be pumped out now. <br /> DRAINFIELD CONDITION (11-14): /if <br /> Drainfield inspection indicates: <br /> 11 Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS (slope.setbacks.etc.): itA77-eii <br /> POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table.etc.): /4a.✓ ,, <br /> COMM NTS: I / 1 <br /> Alpl' c AR I. � is r <br /> I' i•timat tcJ ' Pill ♦f_ ... .r ,l�" 1._rL Aai/.lamt�ha . ve.A..: "u t .�. <br /> �c ilinr s.. ` r'. iyii�.. ���. f.' � �'Vsi - at., i....c7 r. v►, <br /> -- - - / J.'I� "r� sl„- . I <br /> Date of Inspection e, is System nspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly, but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> information. <br /> 1. <br /> This report must be kept on the premises with the system location and pumping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner e <br /> ti <br />