My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1991-003809 - sewer system
Orono
>
Property Files
>
Street Address
>
O
>
Old Long Lake Road
>
0705 Old Long Lake Road - 36-118-23-32-0006
>
Permits/Inspections
>
1991-003809 - sewer system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:02:41 PM
Creation date
4/12/2018 9:11:15 AM
Metadata
Fields
Template:
x Address Old
House Number
705
Street Name
Old Long Lake
Street Type
Road
Address
705 Old Long Lake Road
Document Type
Permits/Inspections
PIN
3611823320006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• S-P TESTING, INC. <br /> 951 KATYDID LANE <br /> ST. MICHAEL, MN 55376 <br /> 497-3566 <br /> Steven B. Schirmers <br /> May 24, 1991 <br /> Anand & Marian Gopinath <br /> 705 Old Long Lake Rd. <br /> Orono, Henn. Co. , MN <br /> This On-Site. Sewage Treatment System is Designed for a Type 1, four <br /> bedroom home in accordance with the Minnesota Pollution Control <br /> Agency Chapter' 7080 and local ordinances. <br /> The soils on this site are typical of SC soils mapped - HbB - Hayden <br /> loam. A seasonally high water table was located at 24" , (mottled <br /> soil ) . Due to the seasonally high water table, a Pressurized Mound <br /> System will need to be installed. The bottom of the rock bed must <br /> be located at least 3 ' above the seasonally high water table. <br /> The soils at a depth of 12" have a percolation rate averaging 15.1 <br /> min/inch and are adequate for treating septic effluent. <br /> A pumping chamber will need to be installed to lift the effluent to the <br /> treatment .area. <br /> The manifold and supply line pipe must have back drainage to the pumping <br /> chamber. The distribution pipes shall have their ends capped. Be sure <br /> the rock and sand fill material are clean. The sod layer below the <br /> entire mounded area must be turned over, just break up the sod, be sure <br /> not to over work. <br /> The power supply and switches must be located outside the manhole and <br /> pumping chamber in a weather proof enclosure. A warning device must be <br /> installed with a light and sound device, this is in case of a pump failure. <br /> (Mercury floats are a good method) . <br /> A lift pump will be needed in the lower level to keep the tanks shallow. <br /> This site has an existing failing system due to the high water table. <br /> The existing tanks are old & must be abandoned, pumped & filled with <br /> soil . The second tank is located under the garage concrete slab. <br /> Cont'd <br /> Soil and Percolation Tests <br /> Septic System Design <br />