Laserfiche WebLink
Door 3:Solid 126 0.250 32 <br /> East&West entry wall:Wood Frame, 16"o.c. 161 19.0 0.0 8 <br /> Window 12:Above-Grade:Metal Frame:Double Pane 23 0.250 6 <br /> West Wall:Wood Frame, 16"o.c. 657 19.0 0.0 27 <br /> Window w100-101:Above-Grade:Metal Frame:Double Pane 13 0.250 3 <br /> Window w104-09 111-114: <br /> Above-Grade:Metal Frame:Double Pane 87 0.250 22 <br /> Window w200-204:Above-Grade:Metal Frame:Double Pane 37 0.250 9 <br /> Door 4: Glass 59 0.250 15 <br /> East chimney:Wood Frame, 16"o.c. 50 19.0 0.0 3 <br /> West chimney:Wood Frame, 16"o.c. 70 19.0 0.0 4 <br /> Basement Wall 1: Solid Concrete or Masonry 181 7.5 7.5 8 <br /> Wall height:9.0' <br /> Depth below grade:9.0' <br /> Insulation depth: 8.0' <br /> Floor 2 balcony:All-Wood Joist/Truss:Over Outside Air 134 60.0 0.0 2 <br /> Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 711 60.0 0.0 13 <br /> Floor 0: Slab-On-Grade:Heated 166 8.3 115 <br /> Insulation depth:6.0' <br /> Furnace 1:Forced Hot Air,90 AFUE <br /> Proposed and Maximum U-Factor Averages <br /> Proposed Maximum <br /> Average U-Factor Allowed U-Factor <br /> Above-Grade Windows and Glass Doors 0.250 0.370 <br /> Includes Foundation Windows>5.6 ft2 <br /> Floors Over Unconditioned Space 0.018 0.033 <br /> COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, <br /> specifications,and other calculations submitted with the permit application. The proposed building has been designed to <br /> meet the 2000 Minnesota Energy Code requirements in RES checkVersion 3.6 Release 1 (formerly MECchec1 and to <br /> comply with the mandatory requirements listed in the RES checklnspection Checklist. <br /> Builder/Designer Date <br />