My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2005-P08574 - new structure
Orono
>
Property Files
>
Street Address
>
O
>
Old Long Lake Road
>
0645 Old Long Lake Road - 36-118-23-32-0004
>
Permits/Inspections
>
2005-P08574 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:02:37 PM
Creation date
4/11/2018 1:05:16 PM
Metadata
Fields
Template:
x Address Old
House Number
645
Street Name
Old Long Lake
Street Type
Road
Address
645 Old Long Lake Road
Document Type
Permits/Inspections
PIN
3611823320004
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STRUCTURAL NOTES <br /> MATERIAL STRENGTHS <br /> Reinforcing Steel Fy= 60,000 p.s.i. (A615 grade 60) <br /> Concrete F'c= Compressive strength in 28 days <br /> 3,000 p.s.i.for footings <br /> 3,500 p.s.i.for interior slabs on grade <br /> 4,000 p.s.i. unless noted <br /> DESIGN LIVE LOADS <br /> Roofs 50 p.s.f. ground snow load <br /> Typical Floors 40 p.s.f. <br /> Basic Wind Speed 90 m.p.h. (3 second gust) <br /> DESIGN CODES - LATEST EDITIONS <br /> International Building Code <br /> Minnesota State Building Code <br /> American Concrete Institute <br /> CRSI Manual of Standard Practice <br /> American Institute of Timber Construction <br /> National Design Specifications for Stress-Graded Lumber and its Fastenings <br /> SOIL BEARING DESIGN VALUE <br /> 2,000 p.s.f. on undisturbed soil or compacted fill for footings. <br /> Bearing value to be verified by a geotechnical engineer. <br /> COORDINATION -ARCHITECTURAL, MECHANICAL AND ELECTRICAL ITEMS <br /> Location, dimensions and details of recesses, depressions, openings and equipment supports <br /> shall be verified by reference to architectural, mechanical and electrical drawings. <br /> TEMPORARY BRACING <br /> Provide temporary lateral support for all walls until walls are adequately braced by floor or roof <br /> structure. <br /> OPENINGS <br /> Verify size and location of all openings with architectural and mechanical drawings. Openings in <br /> floor and roof not shown on structural drawings must be placed between structural members. <br /> FOOTINGS <br /> Wall footings are cast-in-place concrete with continuous reinforcing placed 3"clear of bottom and <br /> sides. Provide 40 diameter lap at all splices and full crossing lap at corners and intersections. <br /> Unless otherwise noted, wall footings are centered under walls and column footings under <br /> columns. Footing elevations shown on plan are to top of footing. Footings for walls, unless <br /> otherwise noted, shall be 10"thick with a minimum projection of 4" each side with 2 -#4 <br /> continuous. <br />
The URL can be used to link to this page
Your browser does not support the video tag.