My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1999-012079 - mechanical
Orono
>
Property Files
>
Street Address
>
O
>
Old Long Lake Road
>
0490 Old Long Lake Road - 36-118-23-34-0010
>
Permits/Inspections
>
1999-012079 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:03:34 PM
Creation date
4/11/2018 11:09:03 AM
Metadata
Fields
Template:
x Address Old
House Number
490
Street Name
Old Long Lake
Street Type
Road
Address
490 Old Long Lake Road
Document Type
Permits/Inspections
PIN
3611823340010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. <br /> Older,Inc. Barb Wiken <br /> Hamel,MN 55340-9691 10-27-99 Page 2 <br /> Project Summary <br /> Project: Barb Wiken Company: Ditter Inc., Cooling and Heating <br /> Client: Barb Wiken Representative: Doug Bjork <br /> Address: 490 Old Long Lake Rd. Address: 820 Tower Drive <br /> City: Wayzata, MN. City: Medina, MN. 55340 <br /> Phone: 476-0326 Phone: (612)478-9558 <br /> Fax: Fax: (612)478-9524 <br /> Design Data <br /> Project Name: Barb Wiken <br /> Reference City: Minneapolis, Minnesota <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 Feet <br /> Elevation Sensible Adj. Factor: 1.000 <br /> Elevation Total Adj. Factor: 1.000 <br /> Outdoor Outdoor Indoor Indoor Grains • <br /> Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference <br /> Winter: -20 N/A N/A 72 N/A <br /> Summer: 95 75 50% 75 36 <br /> Check Figures <br /> Total Building Supply CFM: 1216 CFM per square foot: 0.285 <br /> Square feet of room area: 4,261 Square feet per ton: 1,011.5 <br /> Building Loads <br /> Total heating required with outside air: 90,515 Btuh 90.515 MBH <br /> Total sensible gain: 37,913 Btuh 91 % <br /> Total latent gain: 3,673 Btuh 9 % <br /> Total cooling required with outside air: 41,586 Btuh 3.466 Tons(based on sensible+ latent) <br /> 4.213 Tons(based on 75%sensible capacity) <br /> Notes <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> Wednesday,October 27,1999 <br />
The URL can be used to link to this page
Your browser does not support the video tag.