My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info including old designs
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road South
>
1130 Old Crystal Bay Road South - 09-117-23-14-0007
>
Septic
>
septic info including old designs
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:49:07 PM
Creation date
4/9/2018 2:25:52 PM
Metadata
Fields
Template:
x Address Old
House Number
1130
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
South
Address
1130 Old Crystal Bay Rd S
Document Type
Septic
PIN
0911723140007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. • <br /> • <br /> �-� CITY of ORONO <br /> 'i : ti Municipal Offices <br /> '";:f-.a. G Street Address: <br /> ���• .¢'� Mailing Address: <br /> 'E8f10 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323.0066 <br /> Owner: /1\.o("147%5 C D'wG k\ S <br /> Address: 1 130 0 id Lryi4) 13„y - <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): <br /> 10 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal <br /> Code but does meet the three foot separation requirement,and which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISIS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and <br /> any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-10): ST <br /> Tank inspection indicates: <br /> OPumpout not needed at this time. <br /> 6 Tank must be pumped out this year (city code requires tanks to be pumped out every 3 years. Tank was last pumped 5 M-6 U ). <br /> 7 Solids accumulation in tanks is at a critical a critical level. Tanks should be pumped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank at next pumpout If tanks <br /> have not been pumped out within the last three years,they should be pumped out now. <br /> 10 Inspection pipe is located directly over tank baffle(does not give accurate measurement of solids accumulation). If tanks have not been pumped <br /> out within the last three years,they should be pumped out now. <br /> D IELD CONDITION(11-14): I I <br /> (Ti) Drainfield is dry,no surfacing evident. <br /> 12 Some evidence of surfacing,not critical yet. . • <br /> 13 Drainfield is saturated and visibly discharging untreated eluent to the surface. Contact the City Inspector immediately.Repairs must be <br /> completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> COMMENTS: ��See I oak S 0 k <br /> ce -23S - o\ 01\ctcc. AffirtfOr-OILC - <br /> Date of Inspection <br /> Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee <br /> or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> information. <br />
The URL can be used to link to this page
Your browser does not support the video tag.