My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
septic info
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road South
>
0540 Old Crystal Bay Road South - 04-117-23-42-0030 - New PID
>
Septic
>
septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:12:28 PM
Creation date
3/26/2018 2:40:22 PM
Metadata
Fields
Template:
x Address Old
Address
0540 Old Crystal Bay Rd S
Document Type
Septic
PIN
0411723420030
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1.0.4,. <br /> 0 ..s <br /> . 0 <br /> . CITY of ORONO <br /> ��, �,� ' •���� ti Municipal Offices <br /> )4I •143.-SP,,� CI <br /> tiny Street Address: Mailing Address: <br /> O¢ 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: bet) Tay, v^k Address: 540 0(a Cr Si-c, AqS S . <br /> Cr/ y <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): 1 d~ 3 <br /> 0 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 1ST S y5tt Ab <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal <br /> Code but does meet the three foot separation requirement,and which is not failing or an imminent threat to public health or safety. <br /> O "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and <br /> any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. Wes.), system. <br /> TANK CONDITION(5-10): 6 <br /> Tank inspection indicates: <br /> OPumpout not needed at this time. <br /> Tank must be pumped out this year (city c de requires tanks to be pumped out every 3 years. Tank was last pumped 4-1J.-0 0 ). <br /> 7 Solids accumulation in tanks is at a critical critical level. Tanks should be pumped out as soon as possible. <br /> 8 System is discharging to the surface. T must be pumped out within 48 hours to eliminate surface discharge. <br /> 9 Inspection risers missing-tanks could not inspected. Inspection risers(4"dia.pipe)must be installed in each tank at next pumpout If tanks <br /> have not been pumped out within the last ee years,they should be pumped out now. <br /> 10 Inspection pipe is located directly over baffle(does not give accurate measurement of solids accumulation). If tanks have not been pumped <br /> out within the last three years,they should a pumped out now. <br /> D RAINFIELD CONDITION(11-14): 11 <br /> JODrainfield is dry,no surfacing evident <br /> 12 Some evidence of surfacing,not critical yet. • <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be <br /> completed within 90 days. <br /> 14 Drainfield extent and condition unknown <br /> 1 <br /> COMMENTS: E-.a ST S j stc '-. O K._ wc1.1- S-0i-t, r..S-t- k 8 so..r o..r.d 0 e <br /> C e.9\gsx.�.4 10-1-( u-, 31—).010. <br /> Date of Inspection I Septic System Inspector -: <br /> Note: In the event that this. :lection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee <br /> or certify that an existing sywill continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> information <br />
The URL can be used to link to this page
Your browser does not support the video tag.