2014-00575 - new septic
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road South
>
0535 Old Crystal Bay Road South- 04-117-23-31-0004
>
Septic
>
2014-00575 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:12:11 PM
Creation date
3/26/2018 1:55:15 PM
Metadata
Fields
Template:
x Address Old
Address
0535 Old Crystal Bay Rd S
Document Type
Septic
PIN
0411723310004
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSPECTOR CHECKLIST - Multi flow - Pressure bed <br /> 535 Old Crystal Bay Rd. Oro o <br /> 0 WELL setbacks: 20'to pressure tested sewer line (5 psi for 15 min) <br /> 50'to everything 100'to dispersal area with shallow well <br /> PROPERTY LINES setback: 10'to everything <br /> — <br /> Road setback: outer ditch,or 33'from center of township road,or 65'from center of cnty road <br /> LAKE/BLUFF setback 20'for bluff. Lakes:GD_, RD_,, NE . Protected wetland_. <br /> — <br /> _ Building setbacks: 10'for everything, 20'for dispersal area. <br /> WATER LINE under pressure Sc 10'to bed,tank&sewer line. (else sewer line> 12"below) <br /> O Sewer line&baffle connection (no 90's, 3'between 45s,slope min 1"in 8', max 2"in 8'). <br /> (no depth rep's, cn out every 100', Sch 40 D2665 or F891) <br /> O Septic tank and risers (wa r tight,insulated, proper depth,existing verified by pumping) <br /> mfg 1500 gallons trash trap/multi-flow dose tank <br /> Riser over outlet, riser over inlet, 6"+inspection pipe over any remaining baffles. <br /> 500 gallon Multi-flow un t UV light req'd Yes <br /> Treatment pump 30 gpm 10 head 15.5 gal 31 sec ON 29.5 min OFF <br /> 20 ft 2 inch supply line <br /> 0 timer ON float 18 1 inches from bottom HLA at 75%tank capacity <br /> Dispersal: <br /> O Dose tank risers and piping (water tight,insulated, proper depth,drainback) <br /> mfp 1500 gallons - <br /> 0 dose pump 45 gpm 22 head VERIFY PUMP CURVE 3.7 min ON 9 hr OFF <br /> O float setting drop 14.0 inches 168 gal dose <br /> LABEL pump requiis and drawdown on riser or panel <br /> ElCam lock, weep hole, suPp y line access (no hard 90,pipes reachable from grade-30") <br /> 0 supply pipe sloped 1/8"+, supported by sch40 sleeve, and buried 6"+. <br /> 0 splice box/control panel/ lectricat connections <br /> Bed dimensions 22 X 46.0 <br /> Rock depth below pipe 1 6 inches <br /> ` Rock bottom elevation 12.0 inches from Grade to bottom of rock(max) <br /> El cover depth of 12"+ VERIFY <br /> 7 laterals (1-2'from edge of rock) <br /> _ 1.50 inch pipe size <br /> 3.0 ft lateral spacing <br /> — <br /> 0 3/16 inch perforations (smatter is ok) <br /> O 3.0 ft perforation spall <br /> _ Air inlet at end of laterals, d at top feed manifold. VERIFY <br /> clean outs (deep bed 2'of ) (no hard 90's) <br /> 4'inspection pipe to bottom rock,anchored VERIFY <br /> `' Abandon existing system if Ty Re-use existing tank certification <br /> —_ monitoring plan and type <br /> well abandonment if necessary <br />