Laserfiche WebLink
.4o.zI \ <br /> O0.:k vi,1,;,4,,,„, <br /> CITY of ORONO <br /> pi IA , ',, = <br /> p p & Municipal Offices <br /> 'r <br /> Street Address: Mailing Address: <br /> iCEggOg' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: J'(ans31Address: 535 Old Crystal Bay Rd. S. <br /> Permit #'s: 1904 Dates: 8/14/68 Contractors: E. J. Peterson <br /> (This is ] an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : <br /> 1 Code System: Meets dr exceeds current City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appearslto be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> d) <br /> Non-Compliant System:) System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom <br /> of the drainfield and the saturated soil level. <br /> (The saturated soil level ] has or [ ] has not been identified at this time. If the <br /> saturated soil level hasndt been identified, this classification is subject to revision.) <br /> K CONDITION (5-9) : 5 I <br /> Pumpout not needed atlthis time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging Ito the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is toqated over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tans Maintenance Pumpout the tanks [ ] were or D04. were not confirmed <br /> to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be <br /> watertight, this classifica ion is subject to revision.) <br /> INFIELD CONDITION (11-10 : 11 <br /> 4,A <br /> Drainfield is dry, no Surfacing evident. <br /> 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium <br /> COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water <br /> table. The separation is Olfeet and the system is non-compliant. Repair or replacement of the <br /> septic system is required b12/31/2007. <br /> Date of Inspection is System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this eport does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> 1 Telephone (612) 473-7357 • FAX 473-0510 <br />