My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
alternate septic site design
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road South
>
0500 Old Crystal Bay Road South - 04-117-23-42-0029 - New PID (Division - Was: 540 Old Crystal Bay Rd S)
>
Septic
>
alternate septic site design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:12:23 PM
Creation date
3/23/2018 1:22:14 PM
Metadata
Fields
Template:
x Address Old
Address
0500 Old Crystal Bay Rd S
Document Type
Septic
PIN
0411723420029
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> /011 purple code Mound Design <br /> www.SepticResource.com (vers 15.2) <br /> Property Owner: Brian Merz Date: 8/19/2016 <br /> Site Address: Lot 1, Blk 1 White Oak Funk Add. PID: <br /> Comments: Future Site <br /> instructions: =enter data =adjust if desired = computer calculated - DO NOT CHANGE! <br /> I) 5 bedroom Type I Residential System <br /> 2) 750 GPD design flow <br /> 3) Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks <br /> 4) 2250 Gal Septic tank (code minimum) 2250 Gal Septic tank (design size / LUG req'd) <br /> Tank options: none <br /> 5) 1.2 GPD/ft2 mound sand loading rate contour loading rate of 12 req's a min 62.5 ft. long rockbed <br /> 6) 10.0 ft rockbed width 62.15 ft rockbed length <br /> 7) 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br /> end feed manifold connection <br /> 8) 3 laterals 60.5 feet long 21.0 perfs / lateral 63 perfs total <br /> (1/2 a perf means the first perf starts at the middle feed manifold) <br /> 9) 7/32 inch perfs at 1 feet residual head gives 0.56 gpm flow rate per perforation <br /> for this perf size Et spacing, i* pipe size on line 12, max perfs/lateral = 30 , line#8 must be less --> OK <br /> )o) 4.0 doses per day (4 minimum) <br /> 11) 188 gallons per dose (treatment volume) <br /> 2.00 5x <br /> 12) 2.00 inch diameter laterals must be used to meet"4x pipe volume" requirement <br /> 2.00 3x <br /> 13) feet of 2.0 inch supply line leads to ##### gallons of drainback volume <br /> (Tip: "top feed" manifold to control the drainback) <br /> 14) ######gallons TOTAL pump out volume (treatment+ drainback) <br /> 15) feet vertical lift from pump to mound laterals, leads to a: <br /> 16) 36 GPM @ ##### feet of head, Pump requirement (note: >50gpm may require an extra 3-6'of head) <br /> 17) 750 gal Dose tank (code minimum) 750 gal Dose tank (design size / LUG req'd) at gpi <br /> leads to a <br /> 18) ###### inch swing on Demand float,1 or timed dosing of ##### min ON (confirm pump rate with drawdown <br /> (this delivers Average flow, =70%of Peak design flow) ##### hrs OFF test and adjust as necessary) <br /> 19) 12 inches from bottom of tank to"Pump OFF"float <br /> 20) ######inches from bottom of tank to"Pump ON"float, or 12 inches to "Timer ON"float if time dosed <br /> 21) ###### inches from bottom of tank to"Hi Level"float, or ##### inches to "Hi Levet"float if time dosed <br /> 22) ###### gallons reserve capacity (after High Level Alarm is activated) <br /> i � <br />
The URL can be used to link to this page
Your browser does not support the video tag.