Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
' Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Pipeline Supply Inc. iiit Kvelseth Residence <br /> Hopkins,MN 55343 Page 6 <br /> Total Building Summary Ldads <br /> comment � Area , eSen T�) <br /> Desaion ,. ,. =Qr t . ,'.17---:,:,P016. = air . ti -1 <br /> WINDOW: <br /> Glazing- 1 1388.5 34,159 0 31,359 31,359 <br /> 11G: Door-Wood-Panel 1 52 2,303 0 702 702 <br /> 15A15-Ofcm-10:Wall-Basement, , framing with R-15 sill 1759.5 6,637 0 0 0 <br /> to floor in 2 x 4 cavity,filled core, no board insulation, <br /> plus interior finish, metal studs, 10'flor depth <br /> 12E-Obw:Wall-Frame, R-19 insulation in 2 x 6 stud 325 1,812 0 230 230 <br /> cavity, no board insulation, brick finish,wood studs <br /> 12F-Obw: Wall-Frame, R-21 insulation in 2 x 6 stud 3586 19,113 0 2,238 2,238 <br /> cavity, no board insulation, brick finish,wood studs <br /> rimjoists:Wall- 798 4,252 0 1,322 1,322 <br /> 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 2550 4,182 0 2,499 2,499 <br /> Floor(also use for Knee Walls and P rtition <br /> Ceilings),Vented Attic, No Radiant Barrier, Dark <br /> Asphalt Shingles or Dark Metal, Tar and Gravel or <br /> Membrane, R-50 insulation <br /> 21A-32: Floor-Basement, Concrete slab, any thickness, 2 2196 3,601 0 0 0 <br /> or more feet below grade, no insulatioh below floor, <br /> any floor cover, shortest side of floor Slab is 32'wide <br /> 20P-38: Floor-Over open crawl space or garage, Passive, 594.5 1,462 0 161 161 <br /> R-38 blanket insulation, any cover <br /> Subtotals for structure: 77,521 0 38,511 38,511 <br /> People: 21 4,200 4,830 9,030 <br /> Equipment: 1,187 9,019 10,206 <br /> Lighting: 0 0 0 <br /> Ductwork: 0 0 0 0 <br /> Infiltration: Winter CFM: 0, Summer CFM:10 0 0 0 0 <br /> Ventilation:Winter CFM: 311, Summer CPM: 311 10,887 6,883 2,926 9,808 <br /> Humidification(Winter)22.41 gal/day: 4 8,220 0 0 0 <br /> Total Building Load Totals: 1 96,628 12,270 55,286 67,555 <br /> "•+n a r te.' y.,...T,, ,,r,.a 5 r, :a; .a.� . ,,.. ;i", ",F 'v ,,,:s,...�,.s,.3, a C;...,-r:" ,w..±..f ,....L::� ?i <br /> y. <br /> Total Building Supply FM: 2,453 CFM Per Square ft.: 0.320 <br /> Square ft. of Room Area: 7,657 Square ft. Per Ton: 1,360 <br /> Volume(ft3)of Cond. Space: 1 69,274 <br /> Bumkk> Loads :_ ..N 1 n .,; u ,,_. _ _ Y <br /> Total Heating Required Including Ventilation Air: 96,628 Btuh 96.628 MBH <br /> Total Sensible Gain: 55,286 Btuh 82 % <br /> Total Latent Gain: 12,270 Btuh 18 % <br /> Total Cooling Required Including Ventilatio,Air: 67,555 Btuh 5.63 Tons(Based On Sensible+ Latent) <br /> �_NC#es .r,-, �-sw�s<: ,. ;11:`. .,1.� .,,: C .�,-.,i�" �a."� a, .� ,.as <br /> u� � :jm ,.vs:^�.,.v .. . . ,..�_ ,n,.£� ...,f. ..��.3^_ �"-�,-�� <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manial J 8th Edition,Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> C:\...\Kvalseth (cities).rh9 Friday, August 11, 2017, 10:12 AM <br />