<br /> ' Rhvac-Residential It Ught Commercial HVAC LoadsElite Software Development,Inc.
<br /> Pipeline Supply Inc, Kvalseth Residence
<br /> Hopkins,MN 55343 111P Page 4
<br /> Load Preview Report
<br /> I i iS ,
<br /> sl S
<br /> Net; ft'' Seni Lat Net Sen Htg Cig Actl Duct
<br /> Scope Toni /Ton Area Gain Gain Gain Loss. CFM; CFM: CFM' Size
<br /> Building I 5.63 1,360 7,657 55,286 12,270 67,555 96,628 1,148 2,453 2,453
<br /> System 1 4.07 1,254 5,107 40,434 8,436 48,870 67,461 813 1,841 1,841 18x18
<br /> Ventilation 1,148 4,249 5,397 6,721
<br /> Humidification 5,075
<br /> Zone 1 -Clg.:13%,Htg.:26% 2,196 6,562 1,000 7,562 14,572 213 307 307 7x9
<br /> 1-Basement 2,196 6,562 1,000 7,562 14,572 213 307 307 3-6
<br /> Zone 2-Clg.:87%,Htg.:74% 2,911 42,812 3,187 45,999 41,092 600 2,006 2,006 18x18
<br /> 2-1st Floor 2,911 42,812 3,187 45,999 41,092 600 2,006 2,006 18-6
<br /> System 2 1.56 1,638 2,550 14,852 3,834 18,686 29,167 335 613 613 9x12
<br /> Ventilation 1,778 2,634 4,412 4,166
<br /> Humidification 3,144
<br /> Zone 1 1 2,550 13.074 1,200 14,274 21,857 335 613 613 9x12
<br /> 3-2nd Floor 1 2,550 13,074 1,200 14,274 21,857 335 613 613 6-6
<br /> Sum of room airflows may be greater than system airflow because
<br /> system has multiple zones.
<br /> C:\...\Kvalseth (cities).rh9 Friday, August 11,2017, 10:12 AM