Laserfiche WebLink
gh' II <br /> O O <br /> a :� CITY of ORONO <br /> �\ ' f Ay Municipal Offices <br /> 4 , G <br /> l )� -'4, Street Address: Mailing Address: <br /> '41.1c' iV <br /> .:g0 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> yOwner: � j n kQS/Ok)Sk) Address: 405 Old Crystal Bay Rd. S. <br /> Permit #'s: 44$3 Dates: 7/2/76 Contractors: Day Plbg. <br /> (This is [x] an existing system [ ] new construction) . <br /> SYSTEM COMPLIAN.E (1-3) : 3 <br /> 1 Code S ste : Meets or exceeds current City standards in all respects relating to design, <br /> constructi.n, and location. Appears to be operating properly. <br /> 2 Com.liant • stem: Does not meet all current City standards for new construction, but in <br /> most respeOts appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> 3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom <br /> of the drai field and the saturated soil level. <br /> (The saturated oil level [ Y) has or [ ] has not been identified at this time. If the <br /> saturated soil 1 vel has not been identified, this classification is subject to revision.) <br /> e5,,NK CONDITION ( -9) : 5 <br /> Pumpout not needed at this time. <br /> 6 Solids accu ulation in tanks indicates they should be pumped out this year. <br /> 7 System is d$scharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection 4isers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within thre years, they should be pumped out and risers installed now. <br /> 9 Inspection ipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not ben pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanks [ ] were or [X] were not confirmed <br /> to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be <br /> watertight, this classification is subject to revision.) <br /> s%.INFIELD CONDI ION (11-14) : 11 <br /> 41Y Drainfield is dry, no surfacing evident. <br /> 12 Some evidene of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield s saturated and visibly discharging untreated effluent to the surface. <br /> Contact the ity Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield epctent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium <br /> COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water <br /> table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the <br /> septic system is required by 12/31/2007. <br /> Date of Inspec"tion S=:tic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly,1 but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />