Laserfiche WebLink
1 <br /> ---)07,ii, <br /> ,, <br /> `t CITY of ORONO <br /> r, 4 <br /> \ ,Y ( �'ira i... titi Municipal Offices <br /> v+ A' <br /> 4,G Street Address: Mailing Address: <br /> '9lt'E+sHpg' 2750 Kelley Parkway P.O. Box 66 <br /> / Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: I l/L- a(n/ t1' \ Address: 340 Old Crystal Bay Rd. S. <br /> r <br /> Permit #'s: 6486, 7139 Dates: 9/;9/81, 9/6/83 Contractors: lndry <br /> (This is [ ] an existing system [ ] new construction) . <br /> S STEM COMPLIANCE (1-3) : 1 <br /> Code System: Meets or exceeds urrent City standards in all respects relating to design, <br /> construction, and location. Ap ears to be operating properly. <br /> 2 Compliant System; Does not meat all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning proper'y. <br /> 3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom <br /> of the drainfield and the satur ted soil level. <br /> (The saturated soil level [x] has or [ ] has not been identified at this time. If the <br /> saturated soil level has not been identified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 6 <br /> 5 Pumpout not needed at this time. <br /> c? Solids accumulation in tanks indicates they should be pumped out this year. <br /> System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanks [ ] were or [ ] were not confirmed <br /> to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be <br /> watertight, this classification is subject to revision.) <br /> 02 INFIELD CONDITION (11-14) : 11 <br /> Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not;critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immecfliately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and conditionlunknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : low <br /> COMMENTS: <br /> RH7 , 1/79,9 -0 ' -A1410111 <br /> Date of Inspection --e•tic System Inspector <br /> Note: In the event that this ins4ection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> i <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />