Laserfiche WebLink
-410-------; <br /> O <br /> ,..: ,.,.._ <br /> . _ <br /> CITY of ORONO <br /> it/ Municipal Offices <br /> st4, ' �G Street Address: Mailing Address: <br /> `9$E+gK04' 2150 Kelley Parkway P.O. Box 66 <br /> �--- Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: 7 ) e./YTG I , 1��( ! _ Address: 285 Old Crystal Bay Rd. N. <br /> Permit #'s: 621 Dates: 9/1•/64 Contractors: Coolbroth Sitton <br /> (This is 0(1 an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds current City standards in all respects relating to design, <br /> construction, and location} Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to b designed, located, and constructed in accordance with previous <br /> codes and is functioning p*operly. <br /> 3 Non-Compliant System: Sytem may or may not meet current City standards for design, <br /> construction, or location,I but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom <br /> of the drainfield and the saturated soil level. <br /> (The saturated soil level [%KJ has or [ ] has not been identified at this time. If the <br /> saturated soil level has not been identified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 9 <br /> 5 Pumpout not needed at this Itime. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> O within three years, they should be pumped out and risers installed now. <br /> Inspection pipe is locatedover tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanks [ ] were or [x] were not confirmed <br /> to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be <br /> watertight, this classification is subject to revision.) <br /> DRAINFIELD CONDITION (11-14) : 11 <br /> g Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium <br /> COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 Hoot separation between the drainfield and the seasonal water <br /> table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the <br /> septic system is required by 12/31/2007. 71i <br /> Date2-0-77 <br /> liniks----' <br /> ' of Inspection <br /> 414--------. <br /> s System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />